首页 | 本学科首页   官方微博 | 高级检索  
     


Anatomical predictors for suture-based closure of the patent foramen ovale: A multicenter experience
Authors:Lars S. Witte MD  Mick P. L. Renkens MD  Aleksandra Gąsecka MD  PhD  Abdelhak el Bouziani MD  Robbert J. de Winter MD  PhD  Jan G. P. Tijssen PhD  Pieter R. Stella MD  PhD  Gregor Leibundgut MD  Michiel Voskuil MD  PhD
Affiliation:1. Department of Cardiology, Amsterdam University Medical Centres, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands;2. Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands

1st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland;3. Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands;4. Department of Cardiology, Cantonal Hospital Baselland, Liestal, Switzerland

Abstract:

Background

NobleStitch EL is a novel suture-based technique used for patent foramen ovale (PFO) closure and an alternative to traditional double-disc devices without the need for antithrombotic therapy. However, successful closure rates are still unknown, and certain anatomies may be unfavorable for successful closure.

Aims

We assessed the efficacy of the NobleStitch EL and sought to identify patient-related anatomical features associated with successful suture-based closure.

Methods

We included 55 patients who underwent PFO closure with the NobleStitch EL in The Netherlands and Switzerland. Successful closure was defined as residual right-to-left shunt grade ≤1 with Valsalva maneuver at a cardiac ultrasound. Predefined possible anatomical determinants for effective closure included PFO length, atrial septal aneurysm, PFO entry- and exit diameter.

Results

Successful closure was achieved in 33 patients (60%). The PFO length was shorter in patients with successful closure compared to unsuccessful closure with a median length of 9.6 mm (IQR 8.0–15.0) versus 13.3 mm (IQR 11.4–18.6) on preprocedural ultrasound (p = 0.041) and 9.9 mm (IQR 8.0–13.1) versus 12.5 mm (IQR 9.7–15.4) on angiography (p = 0.049). Additionally, the PFO exit diameter and PFO volume were smaller in patients with successful closure than unsuccessful closure, with a mean diameter of 7.0 ± 3.1 mm versus 9.5 ± 3.8 mm (p = 0.015) and a median volume of 381 mm3 (IQR 286–894) versus 985 mm3 (IQR 572–1550) (p = 0.016).

Conclusion

In our study cohort, the successful PFO closure rate using NobleStitch EL was relatively low (60%). With this alternative procedure, patients with a small PFO driven by a short PFO tunnel length and small exit diameter seem to be eligible for successful suture-based closure.
Keywords:cryptogenic stroke  heartstitch  NobleStitch EL procedure  patent foramen ovale  PFO closure
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号