首页 | 本学科首页   官方微博 | 高级检索  
检索        


Influence of SPECT attenuation correction on the quantification of hibernating myocardium as derived from combined myocardial perfusion SPECT and 18F-FDG PET
Authors:Sebastian Lehner MD  Christian Sussebach MD  Andrei Todica MD  Christopher Uebleis MD  Stefan Brunner MD  Peter Bartenstein MD  Serge D Van Kriekinge PhD  Guido Germano PhD  Marcus Hacker MD
Institution:1. Department of Nuclear Medicine, University of Munich, Munich, Germany
2. Department of Cardiology, University of Munich, Munich, Germany
3. Cedars-Sinai Medical Center, Los Angeles and David Geffen School of Medicine, UCLA, Los Angeles, CA, USA
4. Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, W?hringer Gürtel 18-20, 1090, Vienna, Austria
Abstract:

Background

To evaluate the influence of SPECT attenuation correction on the quantification of hibernating myocardium derived from perfusion SPECT and 18F-FDG PET.

Methods and Results

20 patients underwent rest 99mTc-tetrofosmin perfusion SPECT/CT and 18F-FDG PET/CT. Perfusion images were reconstructed without attenuation correction (NC), with attenuation correction based on the CT from the SPECT/CT (AC_SPECT), and with attenuation correction based on the CT from the PET/CT (AC_PET). Another 56 patients had rest 99mTc-tetrofosmin perfusion SPECT and 18F-FDG PET/CT. Perfusion images were reconstructed as NC and AC_PET. The amounts of hibernating myocardium and scar were quantified with QPS® and corresponding AC and NC normative databases. In both cohorts, perfusion in the inferior wall was higher in the AC scans than without AC. Global and regional values for total perfusion deficit (TPD), hibernation and scar areas did not differ between NC, AC_SPECT, and AC_PET scans. In a retrospective evaluation with 7% cut-off of hibernating myocardium as a condition for revascularization, the therapeutic approach would have been altered in 5 of 56 patients, if the AC_PET approach had been used.

Conclusions

AC of SPECT perfusion scans with an attenuation map derived from PET/CT scans is feasible. If AC is unavailable, perfusion scans should be compared to NC normative databases for assessing TPD, hibernation, and mismatch. It should be taken into account that in approximately 10% of the patients, a therapeutic recommendation based on published thresholds for hibernating myocardium would be altered if NC scans were used as compared to AC scans.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号