摘    要:目的对乳腺纤维腺瘤高频声像图与CDFI的表现进行探讨。方法对75例经手术、病理证实为乳腺纤维腺瘤的高频声像图与CDFI表现进行了回顾性分析并与病理作了一些对照。结果典型的乳腺纤维腺瘤表现为边界清晰、规则光整的椭圆形或圆形肿块,有纤细的包膜回声及侧壁声影,而非典型的乳腺纤维腺瘤可表现为分叶状、形态、边界不规则、毛糙、有角状突起,无明显包膜及侧壁声影,肿块内可出现条索状强光带及钙化回声,压之与周围组织无明显逆向运动。本组血流信号检出率为57.4%(43/75),平均最大流速(14±9.17)cm/s,平均最小流速(4.16±2.9)cm/s,平均RI0.70±0.12。结论乳腺纤维腺瘤部分表现为较典型的图像,诊断符合率高,但部分纤维腺瘤图像表现不典型,较易误诊,通过总结、分析、认识,诊断符合率有望进一步提高。

关 键 词:乳腺纤维腺瘤 高频声像图 彩色多普勒血流显像 诊断
修稿时间:2000-08-16

Evaluation of High Frequency Ultrasonography and CDFI in Diagnosis of Fibroadenoma of Breast
Wang Xiaoyan,He Bangfu,Huang Xianghong. Evaluation of High Frequency Ultrasonography and CDFI in Diagnosis of Fibroadenoma of Breast[J]. Chinese Journal of Ultrasound in Medicine, 2001, 17(2): 127-129
Authors:Wang Xiaoyan  He Bangfu  Huang Xianghong
Abstract:Objective:To evaluate the diagnostic role of high frequency ultrasonography (HFU)and CDFI for breast fibroadenoma of both the male and the female.Methods:HFU and CDFI findings were reviewed and compared with pathologic study in 75 cases confirmed with fibroadenoma of breast.Results:The typical imaging findings of fibroadenoma were in elliptical or round shapes with homogeneous internal echo,and were marginated smoothly with a fine echoic capsule and a lateral wall shadowing.The nontypical imaging findings of fibroadenoma were lobulated,irregular,angular without a capsule and lateral shadowing.The internal echo of the tumor showed hard light strips and calcification.The tumor and its surrounding tissues had no backward movements by pressure,Vmax was (14±9.17)cm/s,Vmin was (4.16±2.9)cm/s,RI was 0.70±0.12.Conclusions:Part of imagings of breast fibroadenoma are typical,the diagnosis rate corresponding with pathology is very high.Part of imagings are not typical,and misdiagnosis rate shall be further improved.
Keywords:Fibroadenoma High frequency ultrasonography Color Doppler flow imagingx