首页 | 本学科首页   官方微博 | 高级检索  
     

CD71荧光抗体和PI染色的微核流式细胞术检测研究
引用本文:杨明杰,周建嫦,李志,杨杏芬,黄俊明,谭小华,曹佳,曾瑞萍. CD71荧光抗体和PI染色的微核流式细胞术检测研究[J]. 卫生研究, 2005, 34(1): 25-28
作者姓名:杨明杰  周建嫦  李志  杨杏芬  黄俊明  谭小华  曹佳  曾瑞萍
作者单位:1. 广东省疾病预防控制中心毒理实验所,广州,510300
2. 第三军医大学军事预防医学院分子毒理学实验室,重庆,400038
3. 中山大学基础医学院医学遗传学教研室,广州,510300
基金项目:中国博士后科研基金(No.2002031289),广东省医学科学技术研究基金(No.B2002006),2003年广东省重点医学科技攻关专项课题基金
摘    要:目的探索CD71荧光抗体和PI染色的微核流式细胞术自动化检测方法。方法采用-85℃甲醇固定细胞,CD71荧光抗体和PI染色,以伯氏疟原虫感染小鼠血细胞为微核模式生物调校流式细胞仪,建立微核流式细胞术检测方法,并对秋水仙素(COL)诱导的小鼠外周血含微核网织红细胞进行了检测。结果所建立的方法能明确分辨外周血含与不含微核的网织红细胞和成熟红细胞,COL处理小鼠的外周血含微核网织红细胞率呈明显的剂量依赖性升高,流式细胞术与显微镜检测的外周血含微核网织红细胞率有良好相关性(r=098)。结论微核流式细胞术检测方法能准确地检测小鼠外周血含微核网织红细胞。

关 键 词:微核  流式细胞术  秋水仙素
文章编号:1000-8020(2005)01-0025-04
修稿时间:2004-03-18

Automatic analysis of micronuclei by flow cytometry using anti-CD71-FITC and PI staining
Yang Ming-jie,Zhou Jian-chang,Li Zhi,Yang Xing-fen,et al.. Automatic analysis of micronuclei by flow cytometry using anti-CD71-FITC and PI staining[J]. Journal of hygiene research, 2005, 34(1): 25-28
Authors:Yang Ming-jie  Zhou Jian-chang  Li Zhi  Yang Xing-fen  et al.
Affiliation:Centers for Disease Control and Prevention of Guangdong Province, Guangzhou 510300, China. ymingjie@sohu.com
Abstract:OBJECTIVE: To explore flow cytometry (FCM) based method for automatic analysis of micronuclei (MN) in cells staining with anti-CD71-FITC and PI. METHODS: Cell were fixed in -85 degrees C methanol and stained with anti-CD71-FITC and PI, instrument was optimized using malaria-infected erythrocytes as biological standards, a FCM based method for automatic analysis of micronuclei was established. In order to estimate the reliability of the method, the frequencies of micronucleated reticulocytes (MN-RET) in peripheral blood of NIH mice treated with colchicine (COL) was detected using the method. RESULTS: Four cell populations, normochromatic erythrocytes (NCE), reticulocytes (RET), micronucleated erythrocytes (MN-NCE) and MN-RET could be clearly resolved on the FL1-FL2 dot plot using this method. COL induced a dose-dependent increases in the frequency MN-RET in peripheral blood. Data obtained manually and automatically showed a strong linear correlation (r = 0.98) as far as the percentage of MN-RET. CONCLUSIONS: The FCM-based automatic technique using FITC-anti-CD71 and PI staining is a reliable tool for micronucleus analysis.
Keywords:micronuclei   flow cytometry   colchicine
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号