首页 | 本学科首页   官方微博 | 高级检索  
     


Differential findings in post-factum dissections of medieval Korean mummies exhibiting similar preservation patterns on computerized tomography images
Authors:Chang Seok Oh  Sang Yoon Lee  In Sun Lee  Yi-Suk Kim  Ki Seok Koh  Dong Hoon Shin
Affiliation:aDepartment of Anatomy, Seoul National University College of Medicine, 28, Yongon-dong, Chongno-gu, Seoul 110-799, South Korea;bInstitute of Forensic Medicine, Seoul National University College of Medicine, 28, Yongon-dong, Chongno-gu, Seoul 110-799, South Korea;cDepartment of Rehabilitation Medicine, Seoul National University Hospital, 28, Yongon-dong, Chongno-gu, Seoul 110-744, South Korea;dDepartment of Radiology, Seoul National University Hospital, 28, Yongon-dong, Chongno-gu, Seoul 110-744, South Korea;eDepartment of Anatomy, Ewha Womans University School of Medicine, 911-1, Mok-6-Dong, Yangcheon-gu, Seoul 158-710, South Korea;fDepartment of Anatomy, Konkuk University School of Medicine, 1, Hwayang-dong, Gwangjin-gu, Seoul 143-701, South Korea
Abstract:In our previous CT and post-factum dissection studies on medieval Korean mummies, well preserved internal organs generally were found to have been displaced to the dorsal side of the body cavity. This movement seems to have been caused by the effect of gravitational force exerted over long burial durations. However, when we recently examined a newly discovered medieval Korean mummy (SN1-2) by CT, most of the mummified organs were found to have remained in their natural positions. Our post-factum dissection of SN1-2 showed that the organs might have undergone expansion by posthumous gas formation, after which they hardened into a stone-like state, which mitigated against their displacement.Similar CT findings were made in the case of a second Korean mummy (KU-1). Since the internal organs within the thoracic cavity were discovered to be in their natural positions, we suspected that they, like those in the case of SN1-2, had also been changed into stony structures. However, the post-factum dissection showed that the internal organs of KU-1 had neither hardened nor been displaced to the back wall of the thoracic cavity, owing possibly to the presence of a pleural adhesion. Overall, our results indicated that CT alone might be inadequate for correct estimation of the preservation status of internal organs in Korean mummies. This calls for further accumulation of dissection data, against which CT diagnoses can be compared and by which they can be improved.
Keywords:Korea   Mummy   Computerized tomography   Post-factum examination   Internal organ
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号