Investigations of peripheral dose for helical tomotherapy
Authors:Steffen Lissner  Kai Schubert  Tilo Wiezorek  Florian Sterzing  Klaus Herfarth  Gabriele Sroka-Perez  Jürgen Debus
Institution:1. Department of Radiation Oncology, University Hospital Heidelberg, Germany;2. Department of Radiotherapy, University Hospital Jena, Germany
Abstract:PurposeWhenever treating a patient with percutaneous radiotherapy, a certain amount of dose is inevitably delivered to healthy tissue. This is mainly due to beam's entry and exit in the region of the target volume. In regions distant from the target volume, dose is delivered by leakage from the MLC and head scatter from the accelerator head and phantom scatter from the target volume (peripheral dose). Helical tomotherapy is a form of radiation therapy with a uniquely designed machine and delivery pattern which influence the peripheral dose. The goal of this work was to investigate peripheral dose in helical tomotherapy. The experiments were used to establish a complex characterization of the peripheral dose.Materials and methodsA 30*30*60cm3 slab phantom and TLD-100 (Lithium fluoride) were used for the experiments. Treatment procedures were generated with the tomotherapy planning system (TPS). Additionally, procedures were created on the Operator Station of the tomotherapy system without a calculation of the dose distribution. The peripheral dose which was produced by a typical tomotherapy treatment plan was measured. Furthermore, these procedures were used to differentiate the parts of the peripheral dose in phantom scatter dose and head scatter and leakage dose. Additionally, the relation between peripheral dose and treatment time and between peripheral dose and delivered dose was investigated. Additionally, the peripheral dose was measured in an Alderson phantom.ResultsDistances of 30cm or more resulted in a decrease of the peripheral dose to less than 0.1% of the target dose. The measured doses have an offset of approximately 1cGy in comparison to the calculated doses from the TPS. The separated head scatter and leakage dose was measured in the range of 1cGy for typical treatments. Furthermore, the investigations show a linear correlation between head scatter leakage dose and treatment time and between scatter dose parts and delivered dose. A peripheral dose of 0.28% of the target dose was measured in the Alderson phantom at a distance of 17.5cm from the edge of the target volume.ConclusionsThe peripheral dose delivered by a tomotherapy treatment is clinically unobjectionable. The measurements confirmed a linear correlation between head scatter and leakage and treatment time and between scatter dose and delivered dose.
Keywords:Peripheral dose  IMRT  tomotherapy  leakage  shielding  periphere Dosis  IMRT  Tomotherapie  Leckdosis  Abschirmung
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号