64层CT手动和自动管电流调节技术在骨盆创伤中的对照研究
引用本文:潘旭红,陈锋,唐小锋,崔程凯,隋旭蕾,冯佩佩. 64层CT手动和自动管电流调节技术在骨盆创伤中的对照研究[J]. 医学影像学杂志, 2011, 21(12): 1884-1886,1891
作者姓名:潘旭红  陈锋  唐小锋  崔程凯  隋旭蕾  冯佩佩
作者单位:山东省烟台市烟台山医院影像科 山东烟台264008
基金项目:该题目为烟台市科技发展计划项目
摘    要:目的:探讨64层CT手动管电流调节技术在骨盆外伤中应用的可行性及其应用价值.方法:对87例骨盆外伤患者采用64层CT进行手动和自动管电流调节技术两种方法扫描,由2名具有资质的影像医师采用双盲法分别对两种扫描方法所获取图像的图像质量、骨折显示情况及辐射剂量进行评价,详细记录所有数据并进行统计学分析.结果:①手动管电流调节技术对骨折线、盆部软组织、VR图像质量和MPR图像质量评分分别为4.00±0.00,2.72±0.44,4.00±0.00,4.00±0.00;自动管电流调节技术对骨折线、软组织、VR和MPR评分分别为4.00±0.00,3.72±0.44,4.00±0.00,4.00±0.00;两种扫描方法对软组织评分有统计学差异(t =9.06,P=0.00);②手动与自动管电流调节技术剂量加权指数CTDIVOL分别为9.05±1.59.15.50±2.74;手动较自动管电流调节技术降低约41.61%,具有统计学差异(t=17.91,P=0.00).结论:在骨盆外伤患者中,64层CT手动管电流调节技术能确保图像质量满足诊断需求,并能有效降低患者的辐射剂量.

关 键 词:体层摄影术.X线计算机  管电流调节技术  骨盆骨折  低剂量  辐射剂量

Comparative study on manual and automatic tube current modulation of 64-slice CT in pelvis trauma
PAN Xu-hong , CHEN Feng , TANG Xiao-feng , CUI Cheng-kai , SUI Xu-lei , FENG Pei-pei. Comparative study on manual and automatic tube current modulation of 64-slice CT in pelvis trauma[J]. Journal of Medical Imaging, 2011, 21(12): 1884-1886,1891
Authors:PAN Xu-hong    CHEN Feng    TANG Xiao-feng    CUI Cheng-kai    SUI Xu-lei    FENG Pei-pei
Affiliation:Department of Radiology, Yantaishan Hospital, Yantai Shandong Province 264001, P.R. China
Abstract:Objective:To discuss the application value of Manual Tube Current Modulation of 64 slices CT in pelvis trau- ma. Methods: 87 cases of pelvis rrauma patients were performed CT scan with manual and automatic tube current modula- tion, the image quality, fracture display and radiation dose were reviewed in double-blind fashion by two radiologists, and compared by statistic analysis. Results: ① The scores of Manual Tube Current Modulation in fracture line, soft tissue, VR and MPR were 4.00±0.00, 2.72±0.44, 4.00±0.00, 4.00±0.00, respectively, whereas the scor's of Automatic Tube Current Modulation were 4.00±0.00, 3.72±0.44, 4.00±0.00, 4.00±0.00; There was a significant difference in revie- wing soft tissue between the two methods ( t =9.06, P =0.00)② The CTDIvol of manual and automatic tube current modulation was 9.05±1.59,15. 50±2.74, respectively. The CTDIvol of manual tube current modulation was lower by 41.61 than that of automatic tube current modulation, there was significant difference ( t = 17.91, P=0.00). Conclu- sion:In pelvis trauma patients, manual tube current modulation can take place of automatic tube current modulation, and it can further decrease the radiation dose suffered by patients.
Keywords:Tomography, X-ray computed  Automatic tube current modulation  Pelvic fracture Low-dose Radiationdosage