首页 | 本学科首页   官方微博 | 高级检索  
     

HemoCue Hb 201+分析仪在手术中的应用
引用本文:刘芳,李轶聪. HemoCue Hb 201+分析仪在手术中的应用[J]. 黑龙江医学, 2011, 35(1): 8-10. DOI: 10.3969/j.issn.1004-5775.2011.01.003
作者姓名:刘芳  李轶聪
作者单位:中国人民解放军第211医院麻醉科,黑龙江,哈尔滨,150086
摘    要:目的 探讨与血气分析仪相比HemoCue Hb 201+分析仪的精确度,并且与麻醉医生凭经验判定输血时机相比使用HemoCue Hb 201+分析仪能否节约术中输血量.方法 随机选取胃癌全麻患者100例,ASA分级Ⅰ~Ⅱ级,年龄46~65岁,体重65~81 kg.选取手术任意时间点,对100例患者同时采用血气分析仪和H...

关 键 词:血红蛋白  血气分析  输血

Use of HemoCue Hb 201+analysator in the Operations
LIU Fang,LI Yi-cong. Use of HemoCue Hb 201+analysator in the Operations[J]. Heilongjiang Medical Journal, 2011, 35(1): 8-10. DOI: 10.3969/j.issn.1004-5775.2011.01.003
Authors:LIU Fang  LI Yi-cong
Affiliation:(Department of Anesthesiology,the No.211 Hospital of PLA,Harbin 150086,CHINA)
Abstract:Objective To investigate the precision of HemoCue Hb 201+ analysator when it was compared with blood gas analysator.Weather by using HemoCue Hb 201+ analysator could save the quantity of blood transfusion or not.Methods 100 patients of aged 46~65,weight 65~81 kg,ASAⅠ~Ⅱ undergoing gastric cancer total correction,were randomly and double-blindly divided into 2 groups(n=50): experience group and equipment group,n=50.Determine the 100 patients′ Hb by the methods of blood gas analysator and HemoCue Hb 201+ analysator;observe the dependability between two methods.In the experience group,the anesthetists decided the time of blood transfusion(this time point was named "instant value" which was determined by HemoCue Hb 201+ analysator).In the equipment group,use HemoCue Hb 201+ analysator to determine Hb.When Hb was <70 g/L,start the blood transfusion.Record 100 patients′ Hb which were determined by two means;record the instant value;record the total blood transfusion units、the mean blood transfusion units、the quantity of the patients weather receiving the blood transfusion or not;record five recovery indexes,including the analepsia time、the highest BT、the lasting time of fever、infection situation and the cut-recovery time.Results The deference of determing Hb by two methods was no statistical meaning.The dependability between two methods was very good.The total blood transfusion units、the mean blood transfusion units and the quantity of the patients receiving the blood transfusion in the experience group were higher than those in the equipment group.The five recovery indexes after operation have no different between two groups.Conclusion The precision of HemoCue Hb 201+ analysator should be very good,which could help saving the blood-using quantity when being used to determine the time of blood transfusion,and could not affect the patients′ recovery after operation.
Keywords:Hb  Blood gas analysator  Blood transfusion
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号