Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes
Authors:Lee Danny W H  Li Anthony C N  Ko Chi-wah  Chu David W  Chan Kang-chung  Poon Chi-ming  Sin Kwok-sang  Leung Kam-fung  Sze Tak-suen  Chan Angus C W  Chung Sydney C S
Institution:Departments of Surgery and Anesthesiology, North District Hospital and Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong SAR, China.
Abstract:BACKGROUND: The variable-stiffness colonoscope incorporates different degrees of stiffness of the insertion tube, which can be adjusted during the examination. Whether its use can lead to reduced procedure-related pain and sedative use is unknown. OBJECTIVE: Our purpose was to compare the use of 3 types of colonoscope with different shaft stiffnesses in relation to procedure-related pain and sedative consumption. DESIGN: Prospective randomized trial. SETTING: Endoscopy unit of a university-affiliated hospital. PATIENTS: Consecutive patients undergoing ambulatory colonoscopy. INTERVENTIONS: Random assignment was made of patients into 3 groups to receive colonoscopic examinations by one of the 3 types of colonoscope: conventional standard adult size, 1.3-m; 1.6-m; and the new variable-stiffness adult size, full-length (1.6-m) colonoscope. A mixture of propofol and afentanil, delivered by a patient-controlled syringe pump, was used for sedation in all groups. MAIN OUTCOME MEASURES: Outcome measures included dose of patient-controlled sedation consumed, pain score, cecal intubation rate, cecal intubation time, requirement of abdominal pressure and change of patients' positions during colonoscopy, and endoscopists and patients' satisfaction scores according to a visual analog scale. RESULTS: A total of 335 patients were randomized. Patients in group 3 used significantly less propofol (in milligrams per kilograms, mean SD]) compared with the other 2 groups (group 1: 1.00 0.75], group 2: 0.93 0.62], and group 3: 0.75 0.65]; P = .02; 1-way analysis of variance). The mean (SD) pain score was also lower in group 3. LIMITATIONS: The endoscopists were not blinded. CONCLUSION: The use of the new variable-stiffness adult-size colonoscope significantly reduced procedure-related pain and doses of sedative medications during colonoscopy.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号