首页 | 本学科首页   官方微博 | 高级检索  
检索        


Determination of accurate stent graft configuration in abdominal aortic aneurysm using computed tomography: a preliminary study
Authors:Ho Chul Kim  Sang Woo Park  Kyoung Won Nam  Hyuk Choi  Eun Jeong Choi  Seungoh Jin  Min Gi Kim  Kyung Sun
Institution:1. Department of Biomedical Engineering, Brain Korea 21 Project for Biomedical Science, College of Medicine, Korea University, Seoul, Republic of Korea;2. Korea Artificial Organ Center, Korea University, Seoul, Republic of Korea;3. Department of Radiology, Konkuk University Hospital, Seoul, Republic of Korea;4. Biomedical Engineering Branch, National Cancer Center, Goyang, Republic of Korea;5. Department of Medical Science (Biomedical Engineering), College of Medicine, Korea University, Seoul, Republic of Korea;6. Department of Radiology, Korea University Medical Center, Anam Hospital, Seoul, Republic of Korea;7. Korea Electrotechnology Research Institute, Ansan, Republic of Korea;8. Department of Electronics and Information Engineering, Korea University, Seoul, Republic of Korea;9. Department of Thoracic and Cardiovascular Surgery, College of Medicine, Korea University, Seoul, Republic of Korea
Abstract:An aortic stent graft is frequently used to cure an abdominal aortic aneurysm (AAA). It is critical to accurately fit the size and shape of the stent graft to the target region on the aorta. Proper sizing and shaping require the measurement of the orthogonal diameter of the target region from medical images. The present study aimed to acquire an accurate three-dimensional (3D) reconstruction of the aorta to determine the shape of the cross-sectional area where the stent graft would be implanted. A conventional geometric-active contour model was enhanced to prevent blurring and to improve edge detection with high noise resistivity. After the segmentation of two-dimensional (2D) images using the model, a 3D-reconstructed configuration of the aorta was achieved using a surface-rendering technique. The model could segment several selected synthetic images more accurately than conventional methods. Also, a 3D-reconstructed configuration of the abdominal aorta could be achieved using boundary coordinates extracted from 2D image segmentation. This preliminary study indicates the utility of the approach in optimizing stent graft configuration for AAA patients, thus enhancing stent graft healing.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号