Motion detection and correction for dynamic 15O-water myocardial perfusion PET studies
Authors:Alexandru Naum  Marko S Laaksonen  Helena Tuunanen  Vesa Oikonen  Mika Teräs  Jukka Kemppainen  Mikko J Järvisalo  Pirjo Nuutila  Juhani Knuuti
Institution:(1) Turku PET Centre, University of Turku, P.O. Box 52, 20521 Turku, Finland;(2) Department of Medicine, University of Turku, Turku, Finland;(3) Department of Clinical Physiology and Nuclear Medicine, University of Turku, Turku, Finland
Abstract:Purpose Patient motion during dynamic PET studies is a well-documented source of errors. The purpose of this study was to investigate the incidence of frame-to-frame motion in dynamic 15O-water myocardial perfusion PET studies, to test the efficacy of motion correction methods and to study whether implementation of motion correction would have an impact on the perfusion results.Methods We developed a motion detection procedure using external radioactive skin markers and frame-to-frame alignment. To evaluate motion, marker coordinates inside the field of view were determined in each frame for each study. The highest number of frames with identical spatial coordinates during the study were defined as ldquonon-movedrdquo. Movement was considered present if even one marker changed position, by one pixel/frame compared with reference, in one axis, and such frames were defined as ldquomovedrdquo. We tested manual, in-house-developed motion correction software and an automatic motion correction using a rigid body point model implemented in MIPAV (Medical Image Processing, Analysis and Visualisation) software. After motion correction, remaining motion was re-analysed. Myocardial blood flow (MBF) values were calculated for both non-corrected and motion-corrected datasets.Results At rest, patient motion was found in 18% of the frames, but during pharmacological stress the fraction increased to 45% and during physical exercise it rose to 80%. Both motion correction algorithms significantly decreased (p<0.006) the number of moved frames and the amplitude of motion (p<0.04). Motion correction significantly increased MBF results during bicycle exercise (p<0.02). At rest or during adenosine infusion, the motion correction had no significant effects on MBF values.Conclusion Significant motion is a common phenomenon in dynamic cardiac studies during adenosine infusion but especially during exercise. Applying motion correction for the data acquired during exercise clearly changed the MBF results, indicating that motion correction is required for these studies.
Keywords:PET  Myocardial blood flow  Motion detection  Motion correction  Physical exercise
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号