Reducing arrhythmias associated with central venous catheter insertion or exchange.
Authors:R K Stuart  J K Baxter  S A Shikora  P Akerman  C Apovian  C Champagne  A Jennings  B R Bistrian
Institution:New England Deaconess Hospital, Harvard Medical School, Boston, Massachusetts.
Abstract:A recent study demonstrated that the incidence of new arrhythmias occurring during central venous catheter insertion or exchange was 41% atrial and 25% ventricular arrhythmias (12% couplets or greater). Over-insertion of the guidewire, causing direct stimulation to the right side of the heart, has been postulated to be the causative factor. A new technique that allows the operator to control the length of guidewire inserted was developed. With this technique on a population of hospitalized patients, similar to those in the previous study, the incidence of atrial arrhythmias decreased to 32% and the incidence of ventricular arrhythmias to 6% (single premature ventricular contractions only). Although this new technique has limitations, there was a dramatic improvement in the incidence of cardiac arrhythmias. These results indicate a need for modifications in the available equipment to avoid the infrequent but life-threatening complication of malignant arrhythmia.