引用本文:段阳,马红丽,丁世斌,孟繁晨,赖树盛,杨本强. 分析不同阅片者解读三维高分辨力增强磁共振减影图像的一致性[J]. 中国介入影像与治疗学, 2013, 10(4): 239-242
作者姓名:段阳  马红丽  丁世斌  孟繁晨  赖树盛  杨本强
作者单位:沈阳军区总医院放射科,辽宁 沈阳 110016;沈阳军区总医院放射科,辽宁 沈阳 110016;沈阳市第六人民医院放射科,辽宁 沈阳 110006;沈阳军区总医院放射科,辽宁 沈阳 110016;沈阳军区总医院放射科,辽宁 沈阳 110016;沈阳军区总医院放射科,辽宁 沈阳 110016
摘    要:目的探讨不同阅片者解读三维高分辨力增强磁共振血管减影(3DCE HR MRSI)图像的一致性。方法对35例脑转移瘤患者分别行单倍和双倍钆布醇对比剂(1.0M,15ml)3DCE HR MRI,以双倍图像减去单倍图像,得到3DCE HR MRSI。比较阅片者A、B和C(拥有不同年限读片经验)对转移病灶数目和解读时间的差异,评价其一致性。结果对于3DCE HR MRSI,阅片者A、B和C的准确率分别为96.86%(185/191)、91.62%(175/191)和98.95%(189/191),每例的平均解读时间分别为(46.00±6.34)s、(33.80±6.78)s和(32.70±5.76)s,差异无统计学意义(P均>0.05)。不同阅片者间的一致性较好(Kappa值为0.883~0.891)。结论不同阅片者解读3D HR CE MRSI具有较好的准确率和一致性。

关 键 词:脑肿瘤  肿瘤转移  减影技术  磁共振成像
收稿时间:2012-06-04
修稿时间:2013-03-02

Intra-observe agreement of interpreting 3D high resolution contrasted enhancement MR subtraction imaging
DUAN Yang,MA Hong-li,DING Shi-bin,MENG Fan-chen,LAI Shu-sheng and YANG Ben-qiang. Intra-observe agreement of interpreting 3D high resolution contrasted enhancement MR subtraction imaging[J]. Chinese Journal of Interventional Imaging and Therapy, 2013, 10(4): 239-242
Authors:DUAN Yang  MA Hong-li  DING Shi-bin  MENG Fan-chen  LAI Shu-sheng  YANG Ben-qiang
Affiliation:Department of Radiology, the General Hospital of Shenyang Military Region, Shenyang 110016, China;Department of Radiology, the General Hospital of Shenyang Military Region, Shenyang 110016, China;Department of Radiology, the Sixth Hospital of Shenyang, Shenyang 110006, China;Department of Radiology, the General Hospital of Shenyang Military Region, Shenyang 110016, China;Department of Radiology, the General Hospital of Shenyang Military Region, Shenyang 110016, China;Department of Radiology, the General Hospital of Shenyang Military Region, Shenyang 110016, China
Abstract:Objective To assess the intra-observer agreement during interpreting of 3D high resolution contrasted enhancement MR subtraction imaging (3D CE HR MRSI).Methods 3D CE HR MRI were obtained in 35 patients with brain metastases by using single- and double-dose Gadobutrol (1.0 M, 15 ml). 3D HR CE MRSI were obtained by subtracting from double-dose 3D HR CE MRI to single-dose 3D HR CE MRI. The number of lesions, the time costing for interpreting 3D HR CE MRI and 3D HR CE MRSI were compared, and the intra-observer agreement among different interpreters (A, B and C, with different imaging interpreting experiences)was analyzed.Results On 3D HR CE MRSI, the accuracy rate of A,B and C was 96.86% (185/191), 91.62% (175/191) and 98.95% (189/191), respectively. The average interpreting time of A, B and C was (46.00±6.34)s, (33.80±6.78)s and (32.70±5.76)s, respectively (P>0.05). Kappa values for different interpreters were from 0.883 to 0.891.Conclusion The intra-observer agreement during interpreting of 3D HR CE MRSI and accuracy for detecting lesions are good.
Keywords:Brain neoplasms  Neoplasm metastasis  Subtraction technique  Magnetic resonance imaging
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《中国介入影像与治疗学》浏览原始摘要信息
点击此处可从《中国介入影像与治疗学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号