Improved pseudo‐continuous arterial spin labeling for mapping brain perfusion
Authors:Marzieh Nezamzadeh PhD  Gerald B. Matson PhD  Karl Young PhD  Michael W. Weiner MD  Norbert Schuff PhD
Affiliation:1. Center for Imaging of Neurodegenerative Diseases, Veterans Affairs Medical Center, San Francisco, California, USA;2. Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA;3. Department of Pharmaceutical Chemistry, University of California, San Francisco, California, USA
Abstract:

Purpose:

To investigate arterial spin labeling (ASL) methods for improved brain perfusion mapping. Previously, pseudo‐continuous ASL (pCASL) was developed to overcome limitations inherent with conventional continuous ASL (CASL), but the control scan (null pulse) in the original method for pCASL perturbs the equilibrium magnetization, diminishing the ASL signal. Here, a new modification of pCASL, termed mpCASL is reported, in which the perturbation caused by the null pulse is reduced and perfusion mapping improved.

Materials and Methods:

improvements with mpCASL are demonstrated using numerical simulations and experiments. ASL signal intensity as well as contrast and reproducibility of in vivo brain perfusion images were measured in four volunteers who had MRI scans at 4 Tesla and the data compared across the labeling methods.

Results:

Perfusion maps with mpCASL showed, on average, higher ASL signal intensity and higher image contrast than those from CASL or pCASL. Furthermore, mpCASL yielded better reproducibility in repeat scans than the other methods.

Conclusion:

The experimental results are consistent with the hypothesis that the new null pulse of mpCASL leads to improved brain perfusion images. J. Magn. Reson. Imaging 2010;31:1419–1427. © 2010 Wiley‐Liss, Inc.
Keywords:MR perfusion imaging  arterial spin labeling  Alzheimer's disease  Brain  pCASL