首页 | 本学科首页   官方微博 | 高级检索  
     

正常青年女性畸变产物耳声发射测试分析
引用本文:杨晓红,金秀丽,马乙心. 正常青年女性畸变产物耳声发射测试分析[J]. 贵州医药, 2002, 26(2): 126-127
作者姓名:杨晓红  金秀丽  马乙心
作者单位:贵阳医学院附属医院耳鼻喉科,550004
摘    要:目的:检查正常青年人DPOAE范围,为临床应用提供良好依据。方法:对30例(60耳)听力正常青年人,用CAPELLA机型耳声发射仪进行DPOAE测试,选择初始音强度L1=70dBSPL,L2=60dBSPL,水平差10dBSPL。结果:DPOAE总检出率为100%,正常青年人DPOAE幅值差距大,显示出明显个体差异,不同频率处DPOAE幅值有所不同,1KHz,8KHz处幅值最大,信噪比各频率均在10dBSPL以上(明显高出3dBSPL)。结论:发现不同频率下DPOAE图形非光滑曲线,而呈双峰型,双耳显著差异(P>0.05).

关 键 词:畸变产物耳声发射 听力测试 听力正常 青年女性

An analysis of DPOAE examination in healthy youth
Yang Xiaohong,Jin Xiuli,Ma Yixin. An analysis of DPOAE examination in healthy youth[J]. Guizhou Medical Journal, 2002, 26(2): 126-127
Authors:Yang Xiaohong  Jin Xiuli  Ma Yixin
Affiliation:Yang Xiaohong,Jin Xiuli,Ma Yixin Department of tolaryngology,The Affiliated Hospital of Guiyang medical college,Guiyang 550004
Abstract:Objective In order to provide basis for clinical use,DPOAE exams were conducted in healthy youth.Methods 30 healthy youth (60 ears) were detected for DPOAE using OAE apparatus of CAPELLA type.L 1 =70 dB SPL,L 2 =60 dB SPL were selected as initial intensities.The level difference was 10dB SPL.Results The total detectable rate of DPOAE was 100%.Significant differences existed between different individuals.The values of amplitude were different for separate frequencies.It was biggest in 1KHz and 8KHz.S/N ratio was higher than 10 dB SPL (significantly higher than 3dB SPL) for all frequencies.Conclusion The curves of DPOAE are not smooth under different frequencies,manifesting 2 peaks feature.No significant differences exist between bilateral ears ( P >0 05)
Keywords:DPOAE Audio-logical exams Healthy youth with normal hearing acuity