呼出气冷凝液中可溶性髓系细胞触发受体-1检测对呼吸机相关性肺炎早期诊断的价值
引用本文:周超,沈美珠,梁永杰,李晓宁,王秋波,王岸,魏丽,薛菲. 呼出气冷凝液中可溶性髓系细胞触发受体-1检测对呼吸机相关性肺炎早期诊断的价值[J]. 临床肺科杂志, 2013, 18(9): 1558-1560
作者姓名:周超  沈美珠  梁永杰  李晓宁  王秋波  王岸  魏丽  薛菲
作者单位:周超 (上海市浦东新区周浦医院呼吸科,上海,201318); 沈美珠 (上海市第六人民医院金山分院呼吸内科,上海,201500); 梁永杰 (上海市东方医院呼吸内科,上海,200120); 李晓宁 (上海市浦东新区周浦医院呼吸科,上海,201318); 王秋波 (上海市浦东新区周浦医院呼吸科,上海,201318); 王岸 (上海市浦东新区周浦医院呼吸科,上海,201318); 魏丽 (上海市浦东新区周浦医院呼吸科,上海,201318); 薛菲 (上海市浦东新区周浦医院呼吸科,上海,201318);
基金项目:上海市金山区科委(项目编号:2011-3-08)上海市浦东新区卫生局卫生科技项目(项目编号:PW2012A-39)
摘    要:目的探讨呼吸机呼出气冷凝液(EVC)中可溶性髓系细胞触发受体-1(sTREM-1)对呼吸机相关性肺炎(VAP)早期诊断的临床意义。方法以37例有创机械通气患者为研究对象,所有患者均在机械通气后第1 d、3 d、7 d应用双抗体夹心酶联免疫吸附法(DAS-ELISA)测定EVC中sTREM-1水平,根据治疗后评估,37例患者被分成非VAP组13例,VAP组24例(其中康复组14例,恶化组10例),应用受试者工作特征曲线(ROC)研究EVC sTREM-1对VAP早期诊断价值。结果第3 d,VAP组血清CRP、EVC sTREM-1均高于非VAP组(P<0.01);与康复组比较,恶化组血清CRP及EVC sTREM-1水平明显升高(P<0.01);第7 d,血清CRP和EVC sTREM-1在恶化组仍处较高水平,与康复组、非VAP组比较,差异有统计学意义(P<0.01),而康复组与非VAP组在第7 d比较无差别(P>0.05)。应用ROC分析,以第3 d EVC sTREM-1 4.70 ng/ml为VAP的早期诊断界值,其敏感度为95.8%,特异度为92.3%。结论连续EVC中sTREM-1检测有助于VAP的早期诊断,而第7 d血清CRP和EVC中sTREM-1水平可能有助于判断VAP的预后(撤机失败和死亡)指标之一。

关 键 词:呼吸机相关性肺炎  可溶性髓系细胞触发受体-1  呼出气冷凝液  诊断

Clinical value of soluble triggering receptor expressed on myeloid cells-1 in the early diagnosis of patients withventilator-associated pneumonia
ZHOU Chao,SHEN Mei-zhu,LIANG Yong-jie,LI Xiao-ning,WANG Qiu-bo,WANG An,WEI Li,XUE Fei. Clinical value of soluble triggering receptor expressed on myeloid cells-1 in the early diagnosis of patients withventilator-associated pneumonia[J]. Journal of Clinical Pulmonary Medicine, 2013, 18(9): 1558-1560
Authors:ZHOU Chao  SHEN Mei-zhu  LIANG Yong-jie  LI Xiao-ning  WANG Qiu-bo  WANG An  WEI Li  XUE Fei
Affiliation:(Department of Respiratory Medicine, Zhoupu Hospital of Pudong New District, Shanghai 201318, China)
Abstract:Objective To discuss the value of soluble triggering receptor expressed on myeloid cells-1 ( sTREM-1 ) in exhaled ventilator condensate (EVC) in the early diagnose of patients with ventilator-associated pneumonia (VAP). Methods sTREM-1 in EVC was determined in 37 adult patients with mechanical ventilation treatment by double antibody sandwich enzyme-linked immunosorbant assay ( DAS-ELISA). The 37 patients were divided into the non-VAP group with 13 cases and the VAP group with 24 cases, and the VAP group included the recovery subgroup ( 14 cases) and the aggravation subgroup ( 10 cases). The levels of sTREM-I in EVC was measured on Day 1, 3 and 7 for all patients. The early diagnostic value was assessed by receiver operating characteristic (ROC) curve analysis. Results On the 3th day, the levels of EVC, sTREM-1 and serum CRP were obviously higher in the VAP group than in the non-VAP group (P 〈 0.01 ). On the 7th day, the levels of EVC, sTREM-1 and serum CRP were still higher in the aggravation subgroup than in the recovery subgroup and the non-VAP group (P 〈 0. 01 ), but there was no significant difference between the non-VAP group and the recovery sub- group (P 〉0. 05). The dividing value of sTREM-1 in the early diagnosis of patients with VAP was 4.70 ng/ml on the 3rd day by ROC curve analysis. The sensitivity was 85.8% , and the specificity was 92.3%. Conclusion The results suggest that the levels of sTREM- 1 in EVC is conducive to the early diagnosis of VAP, and the levels of sTREM-1 in EVC and serum CRP are helpful to estimate the prog- nosis on the 7th day, including ventilator weaning failure and death.
Keywords:ventilator-associated pneumonia  soluble triggering receptor expressed on myeloid cells-1  exhaled ventilator conden-sate  diagnosis