首页 | 本学科首页   官方微博 | 高级检索  
     


Ultrasound features of blunt testicular injury
Authors:Micallef M  Ahmad I  Ramesh N  Hurley M  McInerney D
Affiliation:Department of Radiology, Adelaide and Meath Hospital, Tallaght, 24, Dublin, Ireland.
Abstract:This is a retrospective study of ultrasound examination for patients with blunt scrotal trauma. Fifteen patients were examined over an 18-month period. The purpose of the study was to discover the ultrasonic features of blunt testicular trauma and to distinguish less severe from more severe injury with testicular rupture requiring surgery. Three had ultrasonic findings of acute testicular rupture and this was confirmed by surgery. The ultrasound features of testicular trauma with rupture are irregularity of testicular outline and inhomogeneity of testicular texture. The value of ultrasound in diagnosing patients with testicular rupture and, therefore, requiring urgent surgery is discussed. In our limited study, irregularity of testicular outline was the distinguishing feature of rupture.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号