非离子型造影剂碘过敏反应的预防和处理
引用本文:张远芳,刘国瑞,郭岳霖,方文辉. 非离子型造影剂碘过敏反应的预防和处理[J]. 现代医用影像学, 2003, 12(6): 249-251
作者姓名:张远芳  刘国瑞  郭岳霖  方文辉
作者单位:汕头大学医学院第二附属医院放射科,广东省汕头市,515041
摘    要:目的:对比观察非离子型造影剂优维显在CT增强扫描中的副反应。探讨其机理及临床应用价值。材料与方法:观察受检人数2109例,男1329例,女780例。药物为德国先灵公司生产非离子型造影剂300mgl/ml优维显。造影剂剂量50~80ml,婴幼儿按公斤体重计算(新生儿4ml/kg,婴儿3ml/kg,幼儿1.5ml/kg)。美国MCT/MCTPLUS高压自动注射器,注射速度2~3ml/s,荷兰philip公司Tomoscan,AV.EPPLUS高速螺旋CT。结果:严重过敏性休克4例,占0.19%;碘过敏试验阳性( )26例,占1.2%.其中2例碘试验严重过敏性休克。碘过敏试验(-),也出现不同程度反应:重度过敏性休克2例,占0.09%;中度21例,占0.99%;轻度40例,占1.8%。结论:非离子型造影剂增强扫描前要认真按常规做好碘过敏试验,碘过敏试验有一定的预测价值。值得注意的是非离子型造影剂也不是绝对安全,少数患者也会有不同程度过敏反应。

关 键 词:非离子型造影剂 碘过敏试验 碘过敏反应 严重 优维显 过敏性休克 预防 高速 AV 安全

The Observation and Nursing of the Patients with Allergy in CT Contrast Enhancement
Zhang Yuanfang Liu Guorui Guo Yuelin et al. The Observation and Nursing of the Patients with Allergy in CT Contrast Enhancement[J]. Modern Medical Imagelogy, 2003, 12(6): 249-251
Authors:Zhang Yuanfang Liu Guorui Guo Yuelin et al
Affiliation:Zhang Yuanfang Liu Guorui Guo Yuelin et al Department of Radiology,The Second Affiliated Hospital of Shantou University Medical College,Guangdong 515041
Abstract:Purpose:To observe the side effect of non-inonic contrast media (Ultravist) in CT contrast enhancement and discuss its mechanism and clinic value.Materials and Methods:2019 patients were observed,including 1329 men and 780 women.The non-ionic contrast media we used is Ultravist which is made in Germany.The dose of contrast media for adult is 300mgI/ml 50-80ml;for neonates,it must be calculated by the weight(newborns 4ml/kg,babies 3ml/kg,infants 1 5ml/kg).The type of high pressure injector is MCT/MCTPLUS,which is made in America.The inject speed is 2-3ml/s.The type of CT machine is philip Tomoscan,AV.EP PLUS,which is made in Holand.Results:4 patients had severe allergic shock,which occupy 0 18%;26 patient were positive in iodin allergy test,which occupy 0 12%.And different reaction were occured during the CT contrast enhancement examination in patients with negative iodine allergy test:2 patients had severe allergic shock,which occupied 0 09%;21 had moderate reaction,which occupied 0 99%;and 40 had mild reaction,which were occupied 1 8%.Conclusion:The iodin allergy test must be well done before the CT contrast enhancement examination though it has some value in predicting allergic reactions.But the non-ionic contrast media isn't absolutely safeied and a few patients will have different reation to it.
Keywords:CT Contrast enhancement Ultravist Side effect Observation and nursing