Affiliation:Department of Ophthalmology, Izmir Bozyaka Teaching and Research Hospital, Turkey.
Abstract:AIM: To compare the efficiency and safety of fibrin glue to suture technique in pterygium surgery performed with limbal autograft.METHODS: A prospective randomised clinical trial was carried out in 58 eyes of 58 patients operated for primary nasal pterygium. Autologous conjunctival graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision. In 29 eyes, the transplant was attached to the sclera with a fibrin tissue adhesive (Beriplast P) and in 29 eyes with 8-0 Virgin silk sutures. The Mann-Whitney U test was used for statistical analysis. Postoperative patient discomfort (pain, stinging, watering) and biomicroscopic findings (hyperemia, edema) were graded. Patients were followed up at least for six months.RESULTS: Subconjunctival hemorrhage occured under the graft in one patient in group 1. In seven cases of group 2, sutures were removed at the 15th day because of granulomatous tissue reaction. Patient symptoms were significantly less and biomicroscopic findings were better in group 1. Pterygium recurrence was seen in one case of group 1, and 2 cases of group 2. Average surgery cost was higher (P<0.05) and surgery time was shorter (P<0.05) in fibrin group. CONCLUSION: Using fibrin glue for graft fixation in pterygium surgery causes significantly less postoperative pain and shortens surgery time significantly.
Keywords:fibrin glue   limbal autograft   pterygium surgery
本文献已被 PubMed 等数据库收录!
点击此处可从《国际眼科》浏览原始摘要信息
点击此处可从《国际眼科》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号