首页 | 本学科首页   官方微博 | 高级检索  
检索        

彩色多普勒超声结合三维动态增强磁共振血管造影诊断下肢动脉硬化闭塞症
引用本文:强沁晨,杜湘珂,石坚,宋奕宁,李建国.彩色多普勒超声结合三维动态增强磁共振血管造影诊断下肢动脉硬化闭塞症[J].中国医学影像技术,2005,21(6):887-889.
作者姓名:强沁晨  杜湘珂  石坚  宋奕宁  李建国
作者单位:1. 北京大学人民医院超声科,北京,100044
2. 北京大学人民医院放射科,北京,100044
摘    要:目的探讨彩色多普勒超声结合动态增强MRA对下肢动脉硬化闭塞症的诊断价值.方法23例下肢动脉硬化闭塞症患者经彩色多普勒超声及三维动态增强磁共振血管造影(3D DCE-MRA)检查,与数字减影血管造影检查(DSA)和/或手术结果相对照.结果83个可比节段中,超声检查符合率为72.29%,3D DCE-MRA符合率为53.01%,而超声结合MRA符合率达到84.34%.结论彩色多普勒超声结合3D DCE-MRA能提高下肢动脉硬化闭塞症诊断的准确率.

关 键 词:超声检查  彩色多普勒  血管造影术  磁共振  动脉硬化闭塞症
文章编号:1003-3289(2005)06-0887-03
收稿时间:4/5/2005 12:00:00 AM
修稿时间:2005年4月5日

Color Doppler ultrasound combined with three-dimensional dynamic contrast-enhanced MR angiography in diagnosis of arteriosclerosis obliterans in lower extremity
QIANG Qin-chen,DU Xiang-ke,SHI Jian,SONG Yi-ning and LI Jian-guo.Color Doppler ultrasound combined with three-dimensional dynamic contrast-enhanced MR angiography in diagnosis of arteriosclerosis obliterans in lower extremity[J].Chinese Journal of Medical Imaging Technology,2005,21(6):887-889.
Authors:QIANG Qin-chen  DU Xiang-ke  SHI Jian  SONG Yi-ning and LI Jian-guo
Institution:Department of Ultrasound, Peking University People's Hospital, Beijing 100044, China;Department of Radiology, Peking University People's Hospital, Beijing 100044, China;Department of Radiology, Peking University People's Hospital, Beijing 100044, China;Department of Ultrasound, Peking University People's Hospital, Beijing 100044, China;Department of Ultrasound, Peking University People's Hospital, Beijing 100044, China
Abstract:Objective To investigate the value of color Doppler ultrasound (CDU) combined with three-dimensional dynamic contrast-enhanced magnetic resonance angiography (3D DCE-MRA) in the diagnosis of arteriosclerosis obliterans in lower extremity. Methods Twenty-three patients were examined by CDU and 3D DCE-MRA, and the obtained results were compared with DSA and/or surgery. Results A total of 83 segments of lesions were obtained, the accuracy of CDU and 3D DCE-MRA was 72.29% and 53.01%, respectively, while the accuracy of CDU combined with 3D DCE-MRA was 84.34%. Conclusion CDU combined with 3D DCE-MRA can improve the accuracy of diagnosis in the arteriosclerosis obliterans in lower extremity.
Keywords:Ultrasonography  color Doppler  Angiography  magnetic resonance  Arteriosclerosis obliterans
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号