首页 | 本学科首页   官方微博 | 高级检索  
检索        

穿透角膜移植术各屈光变量及其相互关系
引用本文:王相如,蒋华,张霞,王晓莉.穿透角膜移植术各屈光变量及其相互关系[J].山东大学耳鼻喉眼学报,2008,22(4):373-375.
作者姓名:王相如  蒋华  张霞  王晓莉
作者单位:第二军医大学济南临床医学院 济南军区总医院眼科, 济南 250031
摘    要:目的〓〖HTK〗研究穿透性角膜移植(penertrating keratoplasty,PKP)术后各屈光变量间的数量关系,探讨PKP引起眼球屈光状态变化的规律。〖HTW〗方法〓〖HTK〗32只新西兰大白兔随机分为A、B、C、D四组分别行PKP术,植孔大小均为7mm,植片直径依次为7、7.25、7.5和8.0mm,将屈光变量植片差值、角膜屈折力、角膜厚度、前房深度、晶状体厚度依次设为自变量X1、X2、X3、X4、X5,眼轴长度为应变量Y,分别在术前、术后1周、2周、1月、2月、3月进行观察测量并建立Y与各自变量间的数学模型。〖HTW〗结果〓〖HTK〗术前各屈光变量在各组间无显著差异(P>0.05)。综合各时间点的参数获得了屈光变量间的回归方程,如:术后3月Y=15.238+0.199X1+0.544X2-0.060X3+0.129X4-0.094X5。〖HTW〗结论〓〖HTK〗PKP术中应用不同植片/植孔大小差值可以引起眼球屈光状态的改变。所建立的回归方程数学模型对PKP术后屈光状态的控制具有一定指导作用。

关 键 词:  角膜移植  屈光    

Relationships among different refractive components following penetrating keratoplasty
WANG Xiang-ru,JIANG Hua,ZHANG Xia,WANG Xiao-li.Relationships among different refractive components following penetrating keratoplasty[J].Journal of Otolaryngology and Ophthalmology of Shandong University,2008,22(4):373-375.
Authors:WANG Xiang-ru  JIANG Hua  ZHANG Xia  WANG Xiao-li
Institution:Department of Ophthalmology, Jinan Clinical Medical College, Second Military Medical University, General Hospital of Jinan Military Command of Chinese PLA, Jinan 250031, China
Abstract:Objective〓〖WTBZ〗To explore the relationships among different refractive components following penetrating keratoplasty(PKP) and to evaluate the refractive changes induced by PKP. 〖WTHZ〗Methods〓〖WTBZ〗32 New Zealand white rabbits were divided into groups A, B, C and D. The diameter of the adopt hole was 7.0mm in each group, but the donor diameter was 7.0mm, 7.25mm, 7.5mm and 8.0mm in groups A, B, C and D. The differences of donor button and host bed(Δd), corneal dioptric power, corneal thickness, anterior chamber depth and lense thickness were supposedas cause quantity X1, X2, X3, X4 and X5, and the axial length served as the result quantity. All the refractive components were examined before the operations and 1 week, 2 weeks, 1 month, 2 months and 3 months after the operations. Mathematic models of regression equations were built. 〖WTHZ〗Results〓〖WTBZ〗Before the operations, no statistical differences of the refractive components were found in the four groups. After the operations, the mathematic models of regression equations were built as follows: 3 month after the operations: Y=15.238+0.199X1+0.544X2-0.060X3+0.129X4-0.094X5. 〖WTHZ〗Conclusion〓〖WTBZ〗Different sizes of donor button and host bed (Δd) can induce changes of refractive components during PKP. The established mathematic model of regression equations is helpful in quantifying the refractive error and controlling the refraction of PKP.
Keywords:Rabbits  Corneal transplantation  Refraction  eyes
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《山东大学耳鼻喉眼学报》浏览原始摘要信息
点击此处可从《山东大学耳鼻喉眼学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号