首页 | 本学科首页   官方微博 | 高级检索  
     

心率变异性近似熵分析法与脑电双频谱指数间的相关性
引用本文:周芳,申岱,刘家鹏,贾晓宁,李佩. 心率变异性近似熵分析法与脑电双频谱指数间的相关性[J]. 中国中西医结合外科杂志, 2010, 16(2): 178-180
作者姓名:周芳  申岱  刘家鹏  贾晓宁  李佩
作者单位:1. 天津医科大学,天津,300070
2. 天津医科大学口腔医院麻醉科
摘    要:目的:观察全身麻醉时心率变异性分析中近似熵分析法与脑电双频谱指数(BIS)在监测麻醉深度时的相关性。方法:对40例全身麻醉病人测定麻醉前(T1)、诱导插管(T2)、术中(T3)、苏醒(T4)4个时间点各5min的心率(HR)、平均动脉压(MAP)、脑电双频谱指数(BIS)和近似熵(ApEn)变化。结果:HR在T2、T3和T4均较T1值升高(P0.01~0.05)。MAP在T2时较T1值降低(P0.05),T3、T4较T1值升高(P0.05),而T4比T3明显升高(P0.01)。BIS值在麻醉后各时点均较T1值下降明显(P0.01),其中T4也较T1下降(P0.05),T3与T2时相比明显降低(P0.01),而T4较T3明显升高(P0.01)。近似熵值的T1值均大于其他各时点(P0.01~0.05),其T4较T3时点升高(P0.01),T3较T2时点降低(P0.05)。结论:作为心率变异性的非线性分析方法指标的近似熵分析法,能描述围术期心脏自主神经功能状态的变化,但其与BIS并无相关性。

关 键 词:近似熵  脑电双频谱指数  全身麻醉  心率变异性

Correlation between Monitoring Parameters of Approximate Entropy of Heart Rate Variability and BIS during General Anesthesia
Zhou Fang,Shen Dai,Liu Jiapeng,et al.. Correlation between Monitoring Parameters of Approximate Entropy of Heart Rate Variability and BIS during General Anesthesia[J]. Chinese Journal of Surgery of Integrated Traditional and Western Medicine, 2010, 16(2): 178-180
Authors:Zhou Fang  Shen Dai  Liu Jiapeng  et al.
Affiliation:Zhou Fang,Shen Dai,Liu Jiapeng,et al.Department of Anesthesiology , Stomotology,Hospital of Tianjin Medical University.Tianjin(300070),China
Abstract:Objective To compare the changes of approximate entropy and bispectral index(BIS) during general anesthesia, and to estimate the relationship between approximate entropy and bispectral index.Methods Parameters as heart rate(HR) mean arterial pressure(MAP) BIS and approximate entropy were monitored and recorded before induction T1), induction and intubation(T2), operating 1h(T3) and regain consciousness(T4) of forty patients of ASA 1~II with general anesthesia.Results Compared to T1, the HR was increased at the other time-points.The value of MBP at T2 was lower than that at T1, and at T3 and T4 were higher than that at T1, but the value of T3 was significantly different from that of T4.Compared to T1 the value of BIS at the other time-point was decreased and that at T4 was lower than that at T1,.That at T3 was significantly lower than that at T2, but that at T4 was higher than that at T3.the value of approximate entropy at T1 was higher than at the other time-points and that at T4 was higher than those at T2 and T3, but compared to that at T2 that at T3 was higher.But approximate entropy and BIS had no correlation.Conclusion As the parameter of the nonlinear analysis of heart rate variability, the approximate entropy can describe the changes of the autonomic nerve system functional status, but with no relationship to BIS.
Keywords:approximate entropy  bispectral index  general anesthesia  heart rate variability  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号