首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of the microsphere-method for determination of cardiac output.
Authors:L Segadal  K Svanes
Abstract:Cardiac output was determined by means of radioactive microspheres, 15 +/- 5 microns in diameter. Blood flow in the ascending aorta was measured by an electromagnetic flowmeter. In eight cats thirty-eight simultaneous measurements were made of cardiac output and aortic flow. The observations correlated well (r = 0.89), with a mean difference of 5.2%, probably corresponding to coronary blood flow. Continuous flow recordings showed no alterations in aortic flow during the injections of microspheres; arterial blood pressure and heart rate remained unchanged even after six injections, each consisting of about 2 x 10(5) spheres per kg body weight. Tests for shunting of microspheres were performed and revealed shunt fractions in the systemic circulation of about 8%, with no significant shunting through the lungs. The microsphere method for determining cardiac output is thought to be an accurate method, suitable for small and medium sized animals.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏