前列腺癌放疗的摆位误差分析
引用本文:刘跃平,金晶,王维虎,王淑莲,宋永文,李晔雄.前列腺癌放疗的摆位误差分析[J].临床肿瘤学杂志,2014,19(10):910-912.
作者姓名:刘跃平  金晶  王维虎  王淑莲  宋永文  李晔雄
作者单位:100021.北京中国医学科学院中国协和医科大学肿瘤医院放疗科
基金项目:北京希望马拉松专项基金资助项目( LC2013A01);首都临床特色应用研究资助项目
摘    要:目的 探讨前列腺癌仰卧位放疗时左右、头脚、前后方向的摆位误差及各方向的旋转误差。方法 收集2011年10月至2013年6月接受前列腺癌根治性放疗的患者25例,采用仰卧位体模固定,锥形束CT(CBCT)骨配准校位,分析左右、头脚、前后方向的平均摆位误差及各方向的平均旋转误差。结果 全放疗疗程中每例患者校位9次,共计225次。各方向的平均摆位误差:左右(0.19±0.18)cm,头脚(0.36±0.30)cm,前后(0.21±0.16)cm;其中左右方向摆位误差≥5mm占5.8%,头脚占24.3%,前后占8.0%。各方向旋转误差:轴位(1.07±1.03)°,头脚(0.82±0.66)°,水平(0.79±0.68)°。前5次与后4次摆位及旋转误差比较差异无统计学意义(P>0.05)。结论前列腺癌仰卧位放疗时,头脚摆位误差最大,左右及前后摆位误差相当,旋转误差较小可忽略不计。

关 键 词:前列腺肿瘤  仰卧位  放射治疗  摆位误差
收稿时间:2014-03-23
修稿时间:2014-07-18

Analysis of set-up errors during radiotherapy of prostate cancer
LIU Yueping,JIN Jing,WANG Weihu,WANG Shulian,SONG Yongwen,LI Yexiong.Analysis of set-up errors during radiotherapy of prostate cancer[J].Chinese Clinical Oncology,2014,19(10):910-912.
Authors:LIU Yueping  JIN Jing  WANG Weihu  WANG Shulian  SONG Yongwen  LI Yexiong
Institution:Department of Radiotherapy, Cancer Hospital & Institute,Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100021,China
Abstract:Objective To analyze the set-up errors in the left-right( LR, X axis) , superoinferior ( SI, Y axis) and antero-posterior (AP, Z axis) directions and the rotations during radiotherapy of prostate cancer in the supine position. Methods Twenty-five prostate cancer patients who received radiotherapy from October 2011 to June 2013 were analyzed. All the patients were treated with intensity-modulated radiotherapy ( IMRT) in the supine position after external immobilization using thermoplastic shell. Measurements for set-up errors and rotations in X, Y, Z directions were collected from daily image-guided radiotherapy( IGRT, bony match) pre-treatment. The set-up errors and rotations were analyzed. Results Each patient received 9 fractions of measurement with a total of 225 fractions. Mean set-up errors were (0. 19±0. 18)cm, (0. 36±0. 30)cm, and(0. 21±0. 16)cm in the X, Y and Z axes, respectively. The set-up errors of≥5 mm was 5. 8%, 24. 3%, and 8. 0% of all measured fractions in the X, Y and Z axes, respectively. Mean rota-tions were (1. 07±1. 03)°, (0. 82±0. 66)°, and (0. 79±0. 68)°in the axis, vertical, and lateral directions, respectively. After com-paring the first 5 and the following 4 set-up and rotation errors, there were no significant differences( P〉0. 05) . Conclusion The set-up errors is larger in the Y than in the X and Z axes during radiotherapy of prostate cancer in the supine position. The rotation errors are much smaller and can be omitted.
Keywords:Prostate neoplasms  Supine  Radiotherapy  Set-up errors