TRANSURETHRAL PROSTATECTOMY USING VISTATM BIPOLAR RADIOFREQUENCY SYSTEM: COMPARISON WITH CONVENTIONAL TRANSURETHRAL RESECTION OF THE PROSTATE |
| |
Authors: | X.-D. Li X.-F. Rui G.-H. Li Y.-B. Chen H.-Y. Wu |
| |
Affiliation: | Department of Urology, Sir Run Run Shaw Hospital, College of Medical Sciences, Zhejiang University, Hangzhou, China |
| |
Abstract: | To assess the efficacy and safety of transurethral prostatectomy using VistaTM system, between 2002 and 2004, patients with symptomatic BPH without suspected cancer were treated using the Vista device. The therapeutic effect was retrospective studied compared with patients who were received by TURP. Bipolar resection using the Vista device exhibits a statistically difference in maximum urinary flow rate, RUV, IPSS and QOL(P < .05) 3 and 6 months after operation, and no transurethral resection syndrom occurred. TURP also exhibits a statistically difference in maximum urinary flow rate, RUV, IPSS and QOL(P < .05), but TURS occurred in 2 patients. Compared with TURP, the Vista device shows a statistically less blood loss (P < .05), and longer operation time in prostate enlarged III0(P < .05). The VistaTM system seems to be effective and safe, and especially fit the patients who have a bigger prostate and high risk factors. It appears to be an effective treatment for BPH. Long-term results should be evaluated. |
| |
Keywords: | benign prostatic enlargement bipolar resectoscope TURP |
|
|