Bone mineral density: Methods of measurement and its influence on primary stability of miniscrews
Authors:Mariana Marquezan  Thiago Chon Leon Lau  Claudia Trindade Mattos  Amanda Carneiro da Cunha  Lincoln Issamu Nojima  Eduardo Franzotti Sant'Anna  Margareth Maria Gomes de Souza  Mnica Tirre de Souza Araújo
Institution:aPhD student, Pediatric Dentistry and Orthodontics Department, School of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil ; bResearch student, Pediatric Dentistry and Orthodontics Department, School of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil ; cProfessor, Pediatric Dentistry and Orthodontics Department, School of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
Abstract:Objective:To verify whether bone mineral density (BMD) of cortical bone, trabecular bone, and total bone influence the primary stability of orthodontic miniscrews and to verify whether there is a correlation between the measurement of BMD by cone-beam computed tomography (CBCT) and central dual-energy x-ray absorptiometry (DEXA).Materials and Methods:Twenty bovine bone sections were extracted from the pubic and iliac bones from regions with cortical thicknesses of approximately 1 mm. The BMD of the total bone block was evaluated using two methods: CBCT and DEXA. The BMD of cortical, trabecular, and total bone in the region of interest (ROI) were also evaluated by CBCT. After scanning the bone blocks, 20 self-drilling miniscrews (INP®) 1.4 mm in diameter and 6 mm long were inserted into them. The peak implant insertion torque (IT) was registered. After this, the pull-out test (PS) was performed and the maximum force registered. The Pearson correlation test was applied to verify the correlations between variables.Results:The BMD of the total bone block verified by CBCT and DEXA showed a positive and strong correlation (r  =  0.866, P  =  .000). The BMD of the ROI for cortical bone influenced the IT (r  =  0.518, P  =  .40) and the PS of miniscrews (r  =  0.713, P  =  .001, Table 2). However, the total bone BMD (verified by CBCT and DEXA) and trabecular bone BMD presented weak and not statistically significant correlations with primary stability.Conclusions:There was a positive correlation between total bone block BMD measured by DEXA and CBCT. The cortical BMD influenced the IT and PS.
Keywords:Bone density  Cone-beam computed tomography  Dual-energy x-ray absorptiometry  Miniscrew
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号