首页 | 本学科首页   官方微博 | 高级检索  
检索        


Reliability of reference distances used in photogrammetry
Authors:Muge Aksu  Demet Kaya  Ilken Kocadereli
Institution:aAssistant Professor, Department of Orthodontics, Hacettepe University Faculty of Dentistry, Hacettepe University, Ankara, Turkey ; bResearch Assistant, Department of Orthodontics, Hacettepe University, Ankara, Turkey ; cProfessor and Chair, Department of Orthodontics, Hacettepe University Faculty of Dentistry, Hacettepe University, Ankara, Turkey
Abstract:Objective:To determine the reliability of the reference distances used for photogrammetric assessment.Materials and Methods:The sample consisted of 100 subjects with mean ages of 22.97 ± 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects'' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects'' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment.Results:For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance.Conclusions:For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects.
Keywords:Photogrammetry  Reference distances
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号