首页 | 本学科首页   官方微博 | 高级检索  
检索        


Design of high-performance adaptive objective lens with large optical depth scanning range for ultrabroad near infrared microscopic imaging
Authors:Gongpu Lan  Thomas F Mauger  Guoqiang Li
Institution:1.Department of Ophthalmology and Visual Science, The Ohio State University, Columbus, OH 43212, USA;2.Department of Electrical and Computer Engineering, The Ohio State University, 1330 Kinnear Road., Columbus, OH 43212, USA
Abstract:We report on the theory and design of adaptive objective lens for ultra broadband near infrared light imaging with large dynamic optical depth scanning range by using an embedded tunable lens, which can find wide applications in deep tissue biomedical imaging systems, such as confocal microscope, optical coherence tomography (OCT), two-photon microscopy, etc., both in vivo and ex vivo. This design is based on, but not limited to, a home-made prototype of liquid-filled membrane lens with a clear aperture of 8mm and the thickness of 2.55mm ~3.18mm. It is beneficial to have an adaptive objective lens which allows an extended depth scanning range larger than the focal length zoom range, since this will keep the magnification of the whole system, numerical aperture (NA), field of view (FOV), and resolution more consistent. To achieve this goal, a systematic theory is presented, for the first time to our acknowledgment, by inserting the varifocal lens in between a front and a back solid lens group. The designed objective has a compact size (10mm-diameter and 15mm-length), ultrabroad working bandwidth (760nm - 920nm), a large depth scanning range (7.36mm in air) — 1.533 times of focal length zoom range (4.8mm in air), and a FOV around 1mm × 1mm. Diffraction-limited performance can be achieved within this ultrabroad bandwidth through all the scanning depth (the resolution is 2.22 μm - 2.81 μm, calculated at the wavelength of 800nm with the NA of 0.214 - 0.171). The chromatic focal shift value is within the depth of focus (field). The chromatic difference in distortion is nearly zero and the maximum distortion is less than 0.05%.OCIS codes: (220.0220) Optical design and fabrication, (220.1080) Active or adaptive optics, (080.2468) First-order optics, (080.2740) Geometric optical design, (170.3890) Medical optics instrumentation, (170.6900) Three-dimensional microscopy, (170.1790) Confocal microscopy, (170.4500) Optical coherence tomography
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号