Severe gastric insufflation and consequent atelectasis caused by gas leakage using AIR-Q laryngeal mask airway: A case report
Authors:Yue Zhao  Ping Li  De-Wei Li  Gao-Feng Zhao  Xiang-Yu Li
Affiliation:Yue Zhao, Ping Li, De-Wei Li, Gao-Feng Zhao, Xiang-Yu Li, Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, Guangdong Province, China
Abstract:BACKGROUNDThe airways of patients undergoing awake craniotomy (AC) are considered “predicted difficult airways”, inclined to be managed with supraglottic airway devices (SADs) to lower the risk of coughing or gagging. However, the special requirements of AC in the head and neck position may deteriorate SADs’ seal performance, which increases the risks of ventilation failure, severe gastric insufflation, regurgitation, and aspiration.CASE SUMMARYA 41-year-old man scheduled for AC with the asleep–awake–asleep approach was anesthetized and ventilated with a size 3.5 AIR-Q intubating laryngeal mask airway (LMA). Air leak was noticed with adequate ventilation after head rotation for allowing scalp blockage. Twenty-five minutes later, the LMA was replaced by an endotracheal tube because of a change in the surgical plan. After surgery, the patient consistently showed low tidal volume and was diagnosed with gastric insufflation and atelectasis using computed tomography.CONCLUSIONThis case highlights head rotation may cause gas leakage, severe gastric insufflation, and consequent atelectasis during ventilation with an AIR-Q intubating laryngeal airway.
Keywords:Insufflation   Atelectasis   Laryngeal mask airway   Craniotomy   Case report
点击此处可从《World Journal of Clinical Cases》浏览原始摘要信息
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号