首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of PCBs exposure in human hair using double focusing high resolution mass spectrometry and single quadrupole mass spectrometry
Authors:Barbounis Emmanouil G  Tzatzarakis Manolis N  Alegakis Athanasios K  Kokkinaki Aikaterini  Karamanos Nikos  Tsakalof Andreas  Tsatsakis Aristidis M
Affiliation:Center of Toxicology Science and Research, Division of Morphology, Medical School, University of Crete, 71003 Heraklion, PO Box 1393, Crete, Greece.
Abstract:Polychlorinated biphenyls (PCBs) levels were assessed in human hair samples, originating from two main agricultural regions of Greece. The analysis was performed by gas chromatography-mass spectrometry (GC-MS) and gas chromatography-double focusing high resolution mass spectrometry (GC-DFHRMS). The main analytical procedure involved hair decontamination, solid-liquid extraction and cleanup steps. The recoveries of PCBs ranged from 71.2% to 101.6%, with accuracies greater than 87.5% and the between-run precisions (%RSD) lower than 25% for all analytes. Differences in the frequencies of detection and the median values of PCBs were detected between the examined regions and between the applied analytical techniques. All Peloponnesus' hair examined samples were found positive for each examined PCB, while the percentage of the total positive samples ranged from 86.1% (for PCB 138) to 94.4% (for PCB 28 and 153 congeners) using GC-DFHRMS. The Cretan hair samples were less contaminated (SUM PCBs=0.61 and 1.47pg/mg) unlike the Peloponnesus' samples (SUM PCBs=24.68 and 38.74pg/mg) measured by GC-DFHRMS and GC-MS, respectively. PCBs with high chlorination gave lower concentration values compared to low chlorination PCBs in both populations. No significant differences were observed between women and men. The GC-DFHRMS technique provided higher percentage of positive samples and low PCBs median values, due to higher sensitivity and interferences from isobaric ions in the GC-MS technique and is therefore considered as a powerful tool for such assessments in hair specimens.
Keywords:GC–DFHRMS, gas chromatography–double focusing high resolution mass spectrometry   GC–MS, gas chromatography–mass spectrometry   POPs, persistent organic pollutants   ATSDR, Agency for Toxic Substances and Disease Registry   PCBs, polychlorinated biphenyls   TEF, toxic equivalent factor   HPLC, high performance liquid chromatography   SPE, solid phase extraction   MID, multiple ion detection   FC43, perfluorotributylamine   S/N, signal to noise   RSD, relative standard deviation   LOQ, limits of quantification   LOD, limits of detection   SD, standard deviation   HCHs, sum of α-HCH, β-HCH, γ-HCH, δ-HCH and HCB compounds   DDTs, sum of DDT related compounds (op and pp DDD, op and ppDDE, op and ppDDT)   EPA, Environmental Protection Agency
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号