首页 | 本学科首页   官方微博 | 高级检索  
检索        


Photorefractive keratectomy for low-to-moderate myopia and astigmatism with a small-beam,tracker-directed excimer laser
Institution:1. Mayo Clinic, Rochester, MN, USA;2. University of Vermont, Colchester, VT, USA;3. Shock Trauma Center, University of Maryland School of Medicine, Baltimore, MD, USA;1. Department of Neurology, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA;2. Department of Veterans Affairs Health Care System, Iowa City, Iowa, USA;3. Department of Biostatistics, College of Public Health, University of Iowa, Iowa City, Iowa, USA;4. Department of Neurology, University of Nebraska Medical Center, Omaha, Nebraska, USA
Abstract:ObjectiveTo assess the safety and effectiveness of the Autonomous Technologies Corporation LADARVision excimer laser system for photorefractive keratectomy correction of myopia and astigmatism.DesignA multicenter, prospective, noncomparative case series.ParticipantsThe cohort consisted of 467 eyes corrected for spherical myopia and 211 eyes corrected for myopia with astigmatism.InterventionTreatments were performed at six sites in the United States using a 6-mm ablation zone for spherical myopes and a 5.5-mm zone with a 1.0-mm blend for astigmats.Main outcome measuresVisual acuity, subjective refraction, corneal haze, intraocular pressure, complications, adverse reactions, patient satisfaction, and corneal endothelial changes.ResultsTwelve-month follow-up was available on 414 spherical eyes and 175 astigmatic eyes. The results for spherical eyes with correction between −1 and −5.99 diopters (D) were: uncorrected visual acuity (UCVA) of 20/40 or better achieved by 98.1%, 20/20 or better by 72%, 1.8% lost 2 lines and 0.3% lost greater than 2 lines of best spectacle-corrected visual acuity (BSCVA); 76.4% were within 0.50 D of the target correction and 94.4% were within 1.00 D. The results for myopia with astigmatism with spherical equivalent correction between −1 and −5.99 D were: UCVA of 20/40 or better in 97.4%, 20/20 or better in 61.7%, 2.5% lost 2 lines and no eyes lost greater than 2 lines BSCVA; 73.9% were within 0.50 D of the target correction and 95% were within 1.00 D. For spherical myopes combined with myopic astigmats corrected for 6 to 10 D, results were: UCVA of 20/40 or better in 93.4%, 20/20 or better in 61.2%, 2.3% lost 2 lines and no eyes lost greater than 2 lines of BSCVA; 67.2% were within 0.50 D of the desired correction and 87.8% were within 1.00 D. Refractive stability was achieved between 3 and 6 months for the spherical and astigmatic groups. No eyes had corneal haze graded as moderate or greater, and there was no significant decrease in endothelial cell density.ConclusionsPatients treated for 1 to 10 D of spherical equivalent myopia, with or without astigmatism, showed early refractive stability, excellent UCVA, no significant loss of BSCVA, no loss of endothelial cell density, and very low levels of corneal haze to 12 months after surgery.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号