首页 | 本学科首页   官方微博 | 高级检索  
检索        


Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens
Authors:David P Pi?ero  Vicente J Camps  María L Ramón  Verónica Mateo  Rafael J Pérez-Cambrodí
Institution:Grupo de Óptica y Percepción Visual GOPV.Department of Optics, Pharmacology and Anatomy, University of Alicante, San Vicente del Raspeig, Alicante 03690, Spain;Department of Ophthalmology Oftalmar, Vithas Medimar International Hospital, Alicante 03016, Spain;Foundation for the Visual Quality FUNCAVIS:Fundación para la Calidad Visual, Alicante 03016, Spain;Grupo de Óptica y Percepción Visual GOPV.Department of Optics, Pharmacology and Anatomy, University of Alicante, San Vicente del Raspeig, Alicante 03690, Spain;Department of Ophthalmology Oftalmar, Vithas Medimar International Hospital, Alicante 03016, Spain;Grupo de Óptica y Percepción Visual GOPV.Department of Optics, Pharmacology and Anatomy, University of Alicante, San Vicente del Raspeig, Alicante 03690, Spain;Department of Ophthalmology Oftalmar, Vithas Medimar International Hospital, Alicante 03016, Spain;Foundation for the Visual Quality FUNCAVIS:Fundación para la Calidad Visual, Alicante 03016, Spain
Abstract:

AIM

To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP).

METHODS

Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I).

RESULTS

PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj.

CONCLUSION

Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
Keywords:Mplus  multifocal intraocular lens  keratometry  effective lens position  intraocular lens power
点击此处可从《国际眼科杂志(英文版)》浏览原始摘要信息
点击此处可从《国际眼科杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号