首页 | 本学科首页   官方微博 | 高级检索  
     


Performance of a capnodynamic method estimating effective pulmonary blood flow during transient and sustained hypercapnia
Authors:Thorir Svavar Sigmundsson  Tomas Öhman  Magnus Hallbäck  Eider Redondo  Fernando Suarez Sipmann  Mats Wallin  Anders Oldner  Caroline Hällsjö Sander  Håkan Björne
Affiliation:1.Department of Perioperative Medicine and Intensive Care,Karolinska University Hospital,Stockholm,Sweden;2.Department of Physiology and Pharmacology,Karolinska Institutet,Stockholm,Sweden;3.Maquet Critical Care AB,Solna,Sweden;4.Department of Intensive Care Medicine,Hospital de Navarra,Pamplona,Spain;5.Hedenstierna’s laboratory, Section of Anaesthesiology and Critical Care, Department of Surgical Sciences,Uppsala University,Uppsala,Sweden;6.CIBER de Enfermedades Respiratorias,Instituto de Salud Carlos III,Madrid,Spain
Abstract:The capnodynamic method is a minimally invasive method continuously calculating effective pulmonary blood flow (COEPBF), equivalent to cardiac output when intra pulmonary shunt flow is low. The capnodynamic equation joined with a ventilator pattern containing cyclic reoccurring expiratory holds, provides breath to breath hemodynamic monitoring in the anesthetized patient. Its performance however, might be affected by changes in the mixed venous content of carbon dioxide (CvCO2). The aim of the current study was to evaluate COEPBF during rapid measurable changes in mixed venous carbon dioxide partial pressure (PvCO2) following ischemia–reperfusion and during sustained hypercapnia in a porcine model. Sixteen pigs were submitted to either ischemia–reperfusion (n?=?8) after the release of an aortic balloon inflated during 30 min or to prolonged hypercapnia (n?=?8) induced by adding an instrumental dead space. Reference cardiac output (CO) was measured by an ultrasonic flow probe placed around the pulmonary artery trunk (COTS). Hemodynamic measurements were obtained at baseline, end of ischemia and during the first 5 min of reperfusion as well as during prolonged hypercapnia at high and low CO states. Ischemia–reperfusion resulted in large changes in PvCO2, hemodynamics and lactate. Bias (limits of agreement) was 0.7 (?0.4 to 1.8) L/min with a mean error of 28% at baseline. COEPBF was impaired during reperfusion but agreement was restored within 5 min. During prolonged hypercapnia, agreement remained good during changes in CO. The mean polar angle was ?4.19° (?8.8° to 0.42°). Capnodynamic COEPBF is affected but recovers rapidly after transient large changes in PvCO2 and preserves good agreement and trending ability during states of prolonged hypercapnia at different levels of CO.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号