首页 | 本学科首页   官方微博 | 高级检索  
     


Simple method for determination of terbutaline plasma concentration by high-performance liquid chromatography
Authors:Herring V L  Johnson J A
Affiliation:Department of Clinical Pharmacy, College of Pharmacy, University of Tennessee, Memphis 38163, USA.
Abstract:A method is described in which low nanomolar concentrations of terbutaline in plasma can be quantitated by use of a standard isocratic high-performance liquid chromatography system with electrochemical detection. Samples were prepared for injection by solid-phase extraction and preserved from degradation by addition of glutathione. Terbutaline and internal standard metaproterenol were resolved from plasma constituents on a single C(18) column by ion-pairing chromatography. The method is precise and accurate for measurement of freebase concentrations as low as 4.4 nmol/l (1 ng/ml).
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏