首页 | 本学科首页   官方微博 | 高级检索  
检索        


Aortic valve replacement with the freestyle stentless bioprosthesis with respect to spacial orientation of patient coronary ostia
Authors:Kalangos A  Trigo-Trindade P  Vala D  Panos A  Faidutti B
Institution:Clinic for Cardiovascular Surgery, Division of Cardiology, University Cantonal Hospital of Geneva, Switzerland. Afksendyios.Kalangos@hcuge.ch
Abstract:OBJECTIVE: This study evaluates our results for safety and efficacy of aortic valve replacement using the Freestyle bioprosthesis (Medtronic, Inc, Minneapolis, Minn) with a new modified subcoronary implantation technique. This technique takes into account the spacial orientation of the stentless bioprosthesis in the aortic root with respect to the patient's coronary ostia rather than the native commissures. METHODS: Fifty-two consecutive patients with predominant aortic valve stenosis underwent aortic valve replacement with a Freestyle bioprosthesis by means of the described modified subcoronary technique over a 15-month period. Fifty of them were followed up by means of echocardiography at discharge, 6 months, and 1 year. There were 19 men and 31 women, with a mean age of 76 +/- 7 years (range, 58-87 years). Valve size ranged from 21 to 27 mm. RESULTS: Patients with bicuspid aortic valves had a significantly larger angle between both coronary ostia than patients with tricuspid aortic valves (P =.0001). The peak and mean systolic gradients decreased significantly during the first postoperative year for each valve size (P
Keywords:
本文献已被 PubMed 等数据库收录!