首页 | 本学科首页   官方微博 | 高级检索  
     

应用多普勒导丝技术研究内乳动脉与冠状动脉前降支血流动力学
引用本文:夏勇,李东野,潘德峰,钱文浩,李文华,徐晤,张超群,郝湛军. 应用多普勒导丝技术研究内乳动脉与冠状动脉前降支血流动力学[J]. 中国心血管杂志, 2004, 9(5): 337-338,347
作者姓名:夏勇  李东野  潘德峰  钱文浩  李文华  徐晤  张超群  郝湛军
作者单位:徐州医学院附属医院心内科,江苏,徐州,221002
摘    要:目的 比较内乳动脉(IMA)与冠状动脉前降支(LAD)相关血流动力学参数。方法应用血管内多普勒导丝记录22例患者IMA和LAD的平均峰值流速(APV)、舒张收缩流速比(DSVR),造影测量血管直径(D),计算血流量(F)。结果IMA的APV和DSVR与LAD相比有明显差别[分别为(38±12)cm/s VS(23±7)cm/s,P<0.001;0.6±0.3VS 2.4±1.1,P<0.001)];IMA的D和F明显低于LAD[分别为(2.3±0.4)cm vs(3.2±1.1)cm,P<0.05;(90±12)ml/min vs(260±12)ml/min,P<0.001]。结论IMA收缩期供血为主,血流量小;而LAD舒张期供血为主,血流量大。

关 键 词:多普勒导丝  内乳动脉  冠状动脉  血流动力学
文章编号:1007-5410(2004)05-0337-03
修稿时间:2003-11-28

To compare hemodynamics of internal mammary artery with left anterior descending artery,assessed by intravascular Doppler flow wire
XIA Yong,LI Dong-ye,PAN De-feng,QIAN Wen-hao,LI Wen-hua,XU Wu,ZHANGChao-qun,HAO Zhan-jun. To compare hemodynamics of internal mammary artery with left anterior descending artery,assessed by intravascular Doppler flow wire[J]. Chinese Journal of Cardiovascular Medicine, 2004, 9(5): 337-338,347
Authors:XIA Yong  LI Dong-ye  PAN De-feng  QIAN Wen-hao  LI Wen-hua  XU Wu  ZHANGChao-qun  HAO Zhan-jun
Affiliation:XIA Yong,LI Dong-ye,PAN De-feng,QIAN Wen-hao,LI Wen-hua,XU Wu,ZHANGChao-qun,HAO Zhan-jun. Department of Cardiology,Affiliated Hospital of Xuzhou Medical College,Xuzhou 221002,China
Abstract:Objective To compare hemodyname characteristics of internal mammary artery (IMA) with left anterior descending artery (LAD). Methods Coronary angiography and selective IMA angiography were underwent in 22 patients. Phasic blood flow velocity in the IMA and LAD was measured by intravascular Doppler flow wire. The basal average peak velocity (APV) and diastolic/systolic velocity ratio(DSVR) were compared between IMA and LAD. The diameter of IMA and LAD was measured by using QCA during angiography. The flow volume derived from time velocity integral and diameter was computed. Results APV in LAD was lower than IMA[(23±7)cm/s vs (38±12)cm/s, P<0. 001]. DSR in LAD was higher than IMA(2. 4± 1. 1 vs 0. 6±0. 3, F<0. 001). The diameter and flow volume in LAD were higher than IMA[(3. 2±1. 1)cm vs (2. 3±0. 4)cm, P<0. 005; (260±12)ml/ min vs (90±12)ml/min, P<0. 001,respectively]. Conclusions IMA flow is characterized by a higher in systolic period than that of LAD flow. However, LAD flow is characterized by a higher in diastolic period than that of IMA flow. IMA flow is smaller volume than that of LAD flow.
Keywords:Intracoronary Doppler wire  Internal mammary artery  Coronary artery  Hemodynamics
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏