首页 | 本学科首页   官方微博 | 高级检索  
检索        

大学生动态心肺功能和有氧耐力的关联性
引用本文:李闯涛,高晓嶙,吴东哲,王昊.大学生动态心肺功能和有氧耐力的关联性[J].中国学校卫生,2023,44(2):282-286.
作者姓名:李闯涛  高晓嶙  吴东哲  王昊
作者单位:国家体育总局体育科学研究所,北京 100061
基金项目:国家体育总局体育科学研究所基本科研业务费资助项目19-18
摘    要:目的 通过递增负荷运动试验,筛选能有效评估有氧耐力的动态心肺功能指标。方法 于2019年3—11月,从北京市5所高校随机招募能够理解试验并自愿配合整个测试过程的266名志愿者。采用德国Cortex Metalyzer 3B系统和美国Cheetah NICOM系统实时监测气体代谢和心功能,通过线性递增负荷方案测得最大摄氧量。根据研究设计选取有氧耐力和动态心肺功能指标,采用相关和典型性相关分析两者间的关系。结果 男生最大摄氧量(VO2max)绝对值、VO2max相对值、最大每搏输出量(SVmax)、最大每搏输出量指数(SVImax)均显著高于女生,动态心肺功能指标K值低于女生(t值分别为17.8,10.1,8.5,4.3,-6.3,P值均<0.05)。简单相关发现,VO2max绝对值、VO2max相对值与K值、b值呈负相关,VO2max绝对值、VO2max相对值与SVmax、SVI

关 键 词:心肺功能    运动活动  生长和发育  学生
收稿时间:2022-08-31

Association between dynamic cardiorespiratory fitness and aerobic endurance among university students
Institution:China Institute of Sports Science, Beijing(100061), China
Abstract:  Objective   To screen dynamic cardiorespiratory fitness indices for effective assessment of aerobic endurance using incremental load exercise tests.  Methods   From March to November 2019, 266 volunteers who were able to understand the trial and voluntarily cooperated with the entire testing process were randomly recruited from 5 universities in Beijing. Gas metabolism and cardiac function were monitored in real time using the German Cortex Metalyzer 3B system and the US Cheetah NICOM system, and maximum oxygen uptake was measured by a linear incremental loading scheme. Aerobic endurance and dynamic cardiopulmonary function indices were selected according to the study design, and the relationship between the two indicators was analyzed using correlation and typicality correlation.  Results   The absolute maximum oxygen uptake (VO2max), relative maximum oxygen uptake, maximum stroke volume (SVmax), and maximum stroke volume index (SVImax) were significantly higher in males than in females, and the dynamic cardiopulmonary function index K was significantly lower than in females (t=17.8, 10.1, 8.5, 4.3, -6.3, P < 0.05). Simple correlation revealed that absolute VO2max and relative VO2max were negatively correlated with K and b, and absolute VO2max and relative VO2max were positively correlated with SVmax and SVImax(P < 0.01); Both dynamic cardiopulmonary function indices were significantly correlated with aerobic endurance. Aerobic endurance indexes closely related to dynamic cardiopulmonary function were absolute VO2max, relative VO2max; dynamic cardiopulmonary function indexes closely related to aerobic endurance were K, b, SVmax, SVImax.  Conclusion   Improvement of dynamic cardiorespiratory fitness contributes to the improvement of aerobic endurance, the dynamic cardiorespiratory fitness indices K, b, SVmax, and SVImax can be used as important candidates to predict the assessment of aerobic exercise capacity.
Keywords:
点击此处可从《中国学校卫生》浏览原始摘要信息
点击此处可从《中国学校卫生》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号