首页 | 本学科首页   官方微博 | 高级检索  
     

256层螺旋CT低剂量、低浓度冠状动脉的应用研究
引用本文:万玉珍,董楠,王生伟,贾永庚,陈丽娟,周亮,运彩虹. 256层螺旋CT低剂量、低浓度冠状动脉的应用研究[J]. 中国辐射卫生, 2016, 25(3): 375-377. DOI: 10.13491/j.cnki.issn.1004-714x.2016.03.042
作者姓名:万玉珍  董楠  王生伟  贾永庚  陈丽娟  周亮  运彩虹
作者单位:甘肃省酒泉市人民医院放射科, 甘肃 酒泉 735000
摘    要:目的 探讨应用双低技术-低千伏(100 kV)、低浓度碘对比剂(270 mgI/ml)在冠状动脉CTA检查中的可行性。方法 将入选标准的100例冠状动脉CTA检查患者,分为A、B两组,B组再根据管电压和碘对比剂不同分为B1组和B2组。A组30例为前瞻性心电门控,采用100 kV、270 mgI/ml威视派克对比剂,B组为回顾性心电门控,其中B1组35例采用100 kV、270 mgI/ml威视派克对比剂,B2组35例采用120 kV、370 mgI/ml碘普罗胺对比剂。计算各组有效辐射剂量。结果 平均有效辐射剂量(ED) A组为(1.32±0.012) mSv、B1组为(5.55±1.04) mSv、B2组为(10.57 ±1.07) mSv。A组与B1组间、A组与B2组间及B1组与B2组间均有统计学差异。结论 应用双低技术-低千伏(100kV)、低浓度碘对比剂,在体重指数≤ 25.0 kg/m2条件下,可以有效降低辐射剂量。

关 键 词:X射线计算机  体层摄影术  冠状动脉  辐射剂量  对比剂  
收稿时间:2015-08-10

Study of Clinical Application about Coronary Angiography by Low Dosage and Low Concentration In 256 Layer Spiral CT
WAN Yu-zhen,DONG Nan,WANG Sheng-wei,JIA Yong-geng,CHEN Li-juan,ZHOU Liang,YUN Cai-hong. Study of Clinical Application about Coronary Angiography by Low Dosage and Low Concentration In 256 Layer Spiral CT[J]. Chinese Journal of Radiological Health, 2016, 25(3): 375-377. DOI: 10.13491/j.cnki.issn.1004-714x.2016.03.042
Authors:WAN Yu-zhen  DONG Nan  WANG Sheng-wei  JIA Yong-geng  CHEN Li-juan  ZHOU Liang  YUN Cai-hong
Affiliation:Department of Radiology, Jiuquan, People's Hospital, Jiuquan 735000 China
Abstract:Objective To explore the feasibility of CTA in the coronary arteries with the double low technology, namely lowkV (100 kV) and low concentration of iodine wcontrast agent (270 mgI/ml). Methods In the inclusion criteria, 100 patients with coronary artery CTA examination are divided into A, B two groups. Group B again divided into B1 and B2 group according to the tube voltage and different iodine contrast agent. A group of 30 cases applied the prospective heart switch control, using 100 kV, 270 mgI/ml Visipaque contrast medium, group B applied retrospective heart switch control, including B1 group of 35 cases with 100 kV, 270 mgI/ml Visipaque contrast medium, B2 group of 35 cases with 120 kV, 370 mgI/ml Iopromide contrast agent. Finally, Calonlate the effective radiation dose of groups. Results The mean effective dose (ED) in group A is (1.32±0.012) mSv, B1 is (5.55±1.04) mSv, B2 group is (10.57±1.07) mSv. Between group A and group B1, group A and group B2 and B1 and B2 group, there is statistically significant. Conclusion Under the condition of body mass index of ≤ 25.0 kg/m2 or less, the application of double low technology, low kV (100 kV), low concentration of iodine contrast agent, can effectively reduce the radiation dose.
Keywords:Tomography  X-ray Computer  Coronary Artery  Radiation Dose  Contrast Material  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国辐射卫生》浏览原始摘要信息
点击此处可从《中国辐射卫生》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏