Affiliation: | 1.Department of Radiology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki University School of Medicine, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan ;2.Department of Cardiovascular Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki University School of Medicine, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan ; |
Abstract: | Objective Balloon pulmonary angioplasty (BPA) is used to treat patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH); the goal is to improve pulmonary perfusion. We aimed to evaluate lung perfusion blood volume (PBV) with haemodynamic and exercise-capacity parameters to assess the efficacy of BPA in the treatment of CTEPH. MethodsWe retrospectively studied 33 patients over a 6-year period. DECT pulmonary angiography was performed before and after BPA. DECT provided iodine distribution maps; whole-lung and regional PBV images and quantification were generated using post-processing software. A mosaic pattern suggesting perfusion inhomogeneity is typical in CTEPH. Hypothetically, BPA treatment would promote homogenization that would be reflected in the calculated standard deviation. ResultsLung perfusion images showed decreased heterogeneity after BPA. There was a significant difference before and after BPA in the whole-lung PBV and in the regional standard deviation for pulmonary arterial pressure (R = 0.37, p = 0.032 and R = 0.57, p = 0.006), pulmonary vascular resistance (R = 0.51, p = 0.023 and R = 0.60, p = 0.002), transtricuspid pressure gradient (R = 0.50, p = 0.0028 and R = 0.61, p = 0.0001), brain natriuretic peptide (R = 0.54, p = 0.0012 and R = 0.46, p = 0.0078), and 6-min walking distance (R = 0.59, p = 0.003 and R = 0.26, p = 0.14). The effects were especially pronounced after the first BPA procedure. ConclusionDecreased lung heterogeneity may suggest BPA efficacy in treating CTEPH. After BPA treatment, improved lung PBV and improved regional standard deviation showed a strong positive correlation with haemodynamic parameters and exercise capacity, which also suggests that BPA is effective in treating CTEPH. |