Review on aspects of artificial tactile feedback in laparoscopic surgery
Authors:Sebastian Schostek  Marc O Schurr  Gerhard F Buess
Institution:1. School of Arts, Sciences and Humanities, University of São Paulo, 1000, Arlindo Béttio Avenue, 03.828-000 Ermelino Matarazzo, São Paulo-SP, Brazil;2. Escola Politécnica, University of São Paulo, 158, Trav. 3, Prof. Luciano Gualberto Avenue, 05.508-01, Butantã, São Paulo-SP, Brazil;3. Pontifícia Universidade Católica de São Paulo, 984, Monte Alegre Street, 05.014-901 Perdizes, São Paulo-SP, Brazil
Abstract:Since direct manual tissue palpation is not possible in laparoscopic surgery, feedback information on tactile tissue properties is considerably diminished. Restoring part of the surgeon's sense of touch through devices capable of providing artificial tactile feedback (ATF) is an active field of applied research and development.Despite more than two decades of research, technical development of such devices is still basic, and pre-clinical as well as clinical experience is limited. This article provides an overview of the technological aspects of ATF in laparoscopic surgery, gives background information on principles of human perception of related feedback information, and reviews current research attempts in the field of ATF systems in laparoscopic surgery, broken down into three main system components: tactile sensor, display, and data processing.Tactile sensors have been developed to measure tissue compliance, reveal hidden structures or foreign bodies in tissue through measurement of pressure distribution, and to identify and locate arteries by detecting their pulsation. Furthermore, different solutions for presenting tactile data to the surgeon have been developed. Visual and auditory displays are easy to implement into the operating room equipment, while tactile displays still suffer from difficulties concerning their performance and requirements for clinical usability. The role of the data processing system as the linking component in an artificial tactile feedback system has been identified as crucial for effectiveness of the system and easy reception of tactile data by the surgeon.The investigations on theoretical and technological foundations of ATF have led to an extensive database in recent years. An application-driven development approach will likely be a driving factor in the future evolution of this field.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号