首页 | 本学科首页   官方微博 | 高级检索  
     

空气中三氯苯胺的采集与分析方法的研究
引用本文:汪锡灿 唐拾贵. 空气中三氯苯胺的采集与分析方法的研究[J]. 卫生研究, 1998, 27(2): 87-89
作者姓名:汪锡灿 唐拾贵
作者单位:江苏省卫生防疫站
摘    要:空气中三氯苯胺用50%乙醇吸收,经OV-17和OV-210混合色谱柱分离,电子捕获检测器检测测定。对采样及测定条件,用正交试验进行了优选。方法的检出限为0.01mg/L,当标准溶液浓度为0.5~10mg/L时,相对标准偏差为4.3%~3.7%。线性范围为0.02~40mg/L。采样效率为99.1%~100%。样品在采样管中可稳定15天以上。通过现场试验和验证试验,证明该方法准确可靠、快速简便,完全适用于空气中三氯苯胺的测定。各项试验指标符合劳动卫生监测要求。

关 键 词:三氯苯胺  空气  气相色谱法测定

Study on Method of Sampling and Analysis of Trichloroaniline in the Air
X Wang,S Tang,J Sheng. Study on Method of Sampling and Analysis of Trichloroaniline in the Air[J]. Journal of hygiene research, 1998, 27(2): 87-89
Authors:X Wang  S Tang  J Sheng
Affiliation:Health and Epidemic Prevention of Jiangsu Province, Nanjing, China.
Abstract:Trichloroaniline in the air was collected with 50% ethanol and separated with a column OV-17:OV-210 ECD as a detector. The best conditions of sampling and determining were selected through the orthogonal experimental design. The detectable limit was 0.01 mg/L. When the concentration of trichloroaniline in the air was 0.5-10 mg/L, the relative standard deviation (RSD) was 4.3%-3.7%. There was a linear relation within the range of 0.02-40 mg/L. The sampling efficiency was 99.1%-100%. The samples were stable for at least 15 days. It is proved that this method is accurate, fast, simple and sensitive. It is suitable for the determination of trichloroaniline in the air.
Keywords:trichloroaniline   air   gas chromatograph
本文献已被 CNKI 维普 等数据库收录!