首页 | 本学科首页   官方微博 | 高级检索  
     


Locking plate versus external fixation for type C distal radius fractures:A meta-analysis of randomized controlled trials
Authors:Dong Wang  Lei Shan  Jun-Lin Zhou
Affiliation:Department of Orthopaedics, Beijing Chao-Yang Hospital, No. 8 Workers Stadium Road, Chaoyang District, 100020, Beijing, China
Abstract:

Purpose

Distal radial fracture is one of the most common fractures. Up to now, locking plates (LP) and external fixation (EF) are two conventional surgical approaches to type C radius fracture. Which method is superior has not yet reached a consensus. We try to assess the clinical effectiveness of the two interventions by this meta-analysis.

Methods

We used network to search the PubMed, Embase, and Cochrane Medical Library of randomized controlled clinical trials about the type C distal radius fractures performed according to the search strategy mentioned in Cochrane Handbook 5.1.0 from Jan. 2005 to Jan. 2016. Patients in the experimental group were used LP, in the control group were included EF and other surgical approaches. Publication language was restricted to English. Studies that patient population and surgical indication did not define had been excluded. Studies must report at least one of the outcomes as follow: radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The trials in which participants included children were excluded. We used Jadad study scores to appraise the study.

Results

Seven studies included 162 patients (LP group) and 190 patients (EF group). We compared the radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The radial inclination were revealed a difference favoring LP over EF [WMD = 1.84, 95% CI (0.17, 3.50), p = 0.03] and the palmar tilt and ulnar variance was no significant difference between the two groups [(WMD = 3.61, 95% CI (0.00, 7.23), p = 0.05; WMD = 0.05, 95% CI (?0.99, 1.09), p = 0.93]. The functional activities of range of flexion and extension and range of supination and pronation between the two groups was no difference [WMD = 10.04, 95% CI (?6.88, 26.96), p = 0.24; WMD = 12.53, 95% CI (?9.99, 35.06), p = 0.28].

Conclusion

Locking plate and external fixation is feasible to heal radius type C fracture. We found the small difference between the two groups on imaging examination. The locking plate has the advantage on maintaining reduction, however no significant difference regarding outcomes has been found between the two groups.
Keywords:Locking plate  External fixation  Type C  Distal radius fractures  Meta-analysis
本文献已被 ScienceDirect 等数据库收录!
点击此处可从《中华创伤杂志(英文版)》浏览原始摘要信息
点击此处可从《中华创伤杂志(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号