首页 | 本学科首页   官方微博 | 高级检索  
     


Drug testing in oral fluid-evaluation of sample collection devices
Authors:Langel Kaarina  Engblom Charlotta  Pehrsson Anna  Gunnar Teemu  Ariniemi Kari  Lillsunde Pirjo
Affiliation:National Public Health Institute, Drug Research Unit, Mannerheimintie 166, Helsinki, Finland. kaarina.langel@ktl.fi
Abstract:Nine different oral fluid (OF) collection devices were studied to evaluate their suitability for collecting samples for drug analysis. The devices were Greiner Bio-One, Orasure Intercept, Immunalysis Quantisal, StatSure Saliva.Sampler, Cozart, Sarstedt Salivette, Malvern Medical OraCol, Acro Biotech Salicule, and Varian OraTube. For comparison, OF was also collected into plastic tubes. The volume of collected OF was quantified for samples collected both in vitro and from volunteers. Drug recovery was studied by collecting OF fortified at 1000 ng/mL with amphetamine, 3,4-methylenedioxymethamphetamine, cocaine, Delta(9)-tetrahydrocannabinol, morphine, codeine, diazepam, and alprazolam with the devices in vitro and analyzing the samples with gas chromatography-mass spectrometry. Recovery of ethanol was measured from 0.2% in OF by headspace gas chromatography-flame-ionization detection. The stability of drugs in the samples was studied by analyzing the samples after 0, 14, and 28 days storage. The study shows that there are substantial differences between the OF collection devices on the market. Some are well suited for collecting samples for toxicological analysis, but some give quite poor results.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号