Simple colonoscopy reporting system checking the detection rate of colon polyps
Authors:Jae Hyun Kim  Youn Jung Choi  Hye Jung Kwon  Seun Ja Park  Moo In Park  Won Moon  Sung Eun Kim
Institution:Jae Hyun Kim, Youn Jung Choi, Hye Jung Kwon, Seun Ja Park, Moo In Park, Won Moon, Sung Eun Kim, Department of Internal Medicine, Kosin University College of Medicine, Busan 602-702, South Korea
Abstract:AIM: To present a simple colonoscopy reporting system that can be checked easily the detection rate of colon polyps.METHODS: A simple colonoscopy reporting system Kosin Gastroenterology (KG quality reporting system) was developed. The polyp detection rate (PDR), adenoma detection rate (ADR), serrated polyp detection rate (SDR), and advanced adenoma detection rate (AADR) are easily calculated to use this system.RESULTS: In our gastroenterology center, the PDR, ADR, SDR, and AADR test results from each gastroenterologist were updated, every month. Between June 2014, when the program was started, and December 2014, the overall PDR and ADR in our center were 62.5% and 41.4%, respectively. And the overall SDR and AADR were 7.5% and 12.1%, respectively.CONCLUSION: We envision that KG quality reporting system can be applied to develop a comprehensive system to check colon polyp detection rates in other gastroenterology centers.
Keywords:Colon polyp  Detection rate  Reporting system
本文献已被 CNKI 等数据库收录!
点击此处可从《世界胃肠病学杂志(英文版)》浏览原始摘要信息