首页 | 本学科首页   官方微博 | 高级检索  
     


Acute and nine-month clinical outcomes after "suboptimal" coronary stenting: results from the STent Anti-thrombotic Regimen Study (STARS) registry.
Authors:D E Cutlip  M B Leon  K K Ho  P C Gordon  A Giambartolomei  D J Diver  D M Lasorda  D O Williams  M M Fitzpatrick  A Desjardin  J J Popma  R E Kuntz  D S Baim
Affiliation:University of Rochester Medical Center, New York, USA.
Abstract:OBJECTIVES: This registry collected the 30-day and 9-month clinical outcomes of patients whose coronary stent implantation was suboptimal, and compared them with the cohort of patients with "optimal" stenting in the randomized portion of the STent Anti-thrombotic Regimen Study (STARS) trial. BACKGROUND: Although "optimal" stenting combined with an aspirin and ticlopidine regimen carries a low (0.5%) incidence of subacute stent thrombosis, only limited data are available for patients in whom stents are deployed suboptimally. METHODS: In the STARS, 312 (15.9%) of 1,965 patients enrolled were excluded from participation in the randomized trial based on a perceived "suboptimal" result of coronary stenting. Of these, 265 patients met prespecified criteria for suboptimal stenting, and were followed in a parallel registry, which was compared with the randomized STARS optimal stenting cohort. The primary end point was a 30-day composite of death, emergent target lesion revascularization, angiographic thrombosis of the target vessel without revascularization and nonfatal myocardial infarction (MI) unrelated to direct procedural complications. RESULTS: Registry patients had a similar frequency of the primary end point compared with the overall randomized cohort (3.0% vs. 2.2%), with this end point correlating to use of multiple stents, smaller final lumen diameter and absence of ticlopidine from the poststent regimen. Overall 30-day mortality (1.1% vs. 0.06%, p = 0.009) and periprocedural non-Q wave MI (8.7% vs. 4.2%, p = 0.003) were more frequent in registry patients, and appeared to be related to acute procedural complications. Clinical restenosis was significantly higher for registry patients (26.8% vs. 16.0%, p = 0.001), relating to greater prevalence of independent predictors such as smaller final lumen diameter and multiple stent use. CONCLUSIONS: In the STARS registry, the inability to perform optimal stenting correlated with smaller final lumen diameter and longer stent length. With ticlopidine-containing regimens, the acute clinical results of "suboptimal" stent deployment are clinically acceptable, although they are not quite as good as those of optimal stenting using similar drug therapy.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号