首页 | 本学科首页   官方微博 | 高级检索  
检索        


Differences in the erythrocyte aggregation level between veins and arteries of normolipidemic and hyperlipidemic individuals
Authors:Guy Cloutier  Xiaoduan Weng  Ghislaine O Roederer  Louis Allard  Francine Tardif  Raymond Beaulieu
Institution:

? Laboratory of Biomedical Engineering, Institut de recherches cliniques de Montréal, Montréal, Québec, Canada

? Laboratory of Hyperlipidemia and Atherosclerosis, Institut de recherches cliniques de Montréal, Montréal, Québec, Canada

* Service of echo-Doppler, Institut de recherches cliniques de Montréal, Montréal, Québec, Canada

§ Division of Oncology and Hematology, Hôtel-Dieu of Montreal Hospital, Montréal, Québec, Canada

Abstract:The objectives of this study were to detect differences in the Doppler power backscattered by blood in vivo, and to identify factors affecting the backscattered power. The main hypothesis was that variations in the erythrocyte aggregation level between veins and arteries of normolipidemic and hyperlipidemic individuals can be detected with power Doppler ultrasound. Doppler measurements were performed at 5 MHz, with an Acuson 128 XP/10 system, over the carotid artery and jugular vein, external iliac artery and vein, common femoral artery and vein and popliteal artery and vein. Doppler signals were recorded at the center of each vessel to optimize the detection of erythrocyte aggregation, and processed off-line to obtain the backscattered power. The power of each recording was compensated for Doppler gain differences, tissue attenuation with depth and transmitted power variations occurring with pulse-repetition interval modifications. Results showed statistically stronger backscattered power in veins compared to arteries for the iliac, femoral and popliteal sites. In comparison with healthy subjects, stronger powers were observed in hyperlipidemic patients for the femoral and popliteal sites. Power differences were also found between peripheral measurements. On the other hand, no difference was observed between the power measured in the carotid artery and jugular vein for both groups of individuals. Multiple linear regression analyses were performed to identify factors affecting the backscattered power. Results showed a correlation (r) of 71.2% between the Doppler power in the femoral vein and the linear combination of two parameters: an erythrocyte aggregation index S10 measured with a laser scattering method, and the diameter of the vessel measured on B-mode images. Statistically significant linear correlation levels were also found between S10 and the Doppler power in various vessels. In conclusion, this study showed that power Doppler differences exist in vivo in large vessels between veins and arteries of normolipidemic and hyperlipidemic individuals. The Doppler power variations were also shown to be related to erythrocyte aggregation.
Keywords:Spontaneous echo contrast  Acoustic backscattering  Red cell aggregation  Power Doppler ultrasound  Hyperlipidemia  Blood flow  Hemodynamics  Biorheology
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号