首页 | 本学科首页   官方微博 | 高级检索  
     


Diagnostic role of fine-needle aspiration of pancreatic allograft to detect rejection
Authors:Sariya Dinesh  Kluskens Larry  Assad Lina  Treaba Diana  Reddy Vijaya  Gattuso Paolo
Affiliation:Department of Pathology, Rush-Presbyterian-St Luke's Medical Center and Rush Medical College, Chicago, Illinois 60612, USA.
Abstract:The purpose of this study was to assess whether the same principles to evaluate renal transplant by fine-needle aspiration (FNA) for rejection could be applied to pancreatic allograft. Between 1996-1998, 25 ultrasound-guided FNAs on 13 patients with pancreatic allograft were performed and ThinPrep made. The percentage of lymphocytes, lymphoblasts, monocytes, eosinophils, plasma cells, immunoblasts, and macrophages were calculated. Simultaneous peripheral smear was obtained and "total corrected increment" score calculated. Subsequent core biopsy was available in six patients. A total of seven FNAs on three patients were inadequate because of insufficient epithelial cells. No evidence of rejection reported in nine patients was confirmed on biopsy in five patients. One patient reported as suspicious later showed rejection on biopsy. Thus, FNA may be used to monitor the graft status with faster turnaround times. Rejection may be a focal process and FNA may be used for sampling multiple sites. Cytologic diagnosis fairly accurately detects early rejection. Core biopsies are warranted in unsatisfactory specimens and when FNA is suspicious for rejection.
Keywords:pancreas  fine‐needle  rejection
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号