摘    要:目的通过动物活体实验探索内镜超声引导下哑铃样金属支架(LAMS)置入后胆囊取石的安全性与可行性。方法选择体重30~35 kg小型猪6头,静脉麻醉下经腹部开放手术于胆囊内分别置入直径0.8~2.0 cm无菌人结石2~4枚,缝合胆囊及腹腔。造模成功后内镜超声引导下置入LAMS。超细内镜经胃越过支架进入胆囊后寻找结石并取出。经内镜乳头括约肌切开术(EST)及经内镜胆道内支架引流术(ERBD)预防胆漏。再以普通内镜拔出LAMS,金属夹封闭胃壁创面。观察技术成功率、操作时间及并发症发生情况。结果5头猪在内镜超声引导下成功置入LAMS,超细内镜顺利进入胆囊,取石网篮取出直径小于1 cm结石,大结石经激光碎石后完全取出。操作总时间为87~128 min。术后观察无出血、穿孔、感染、胆瘘等并发症发生。另1头猪置入LAMS失败,由于先行EST加ERBD,造成胆囊体积缩小并远离胃腔,穿刺困难。结论内镜超声引导下经胃-胆囊置入LAMS后超细内镜取出胆囊结石技术安全可行,可为行胆囊切除术困难者提供一种新的治疗途径。

关 键 词:动物实验  胆囊结石病  超细内镜  哑铃样金属支架  内镜取石术
收稿时间:2019-01-02
修稿时间:2019-12-30

Animal experimental study of endoscopic cholecystolithotomy after lumen-apposing metal stent implantation (with video)
Yang Junjie,Liu Xiongchang,Chen Xiaoqin,Liu Tianrang,Zhang Qiyong,Wu Deming,Dong Chengpeng,Jin Dacheng and Gou Yunjiu. Animal experimental study of endoscopic cholecystolithotomy after lumen-apposing metal stent implantation (with video)[J]. Chinese Journal of Digestive Endoscopy, 2020, 37(3): 200-204
Authors:Yang Junjie  Liu Xiongchang  Chen Xiaoqin  Liu Tianrang  Zhang Qiyong  Wu Deming  Dong Chengpeng  Jin Dacheng  Gou Yunjiu
Affiliation:(Endoscopy Center,Lanzhou First People′s Hospital,Lanzhou 730050,China;Department of Gastroenterology,Lanzhou Second People′s Hospital,Lanzhou 730046,China;Lanzhou Institute of Animal Husbandry and Veterinary Medicine,Chinese Academy of Agricultural Sciences,Lanzhou 730050,China;Department of Thoracic Surgery,Gansu Provincial Hospital,Lanzhou 730000,China)
Abstract:Objective To investigate the safety and feasibility of endoscopic cholecystolithotomy after endoscopic ultrasonography (EUS) guided gastric-gallbladder stent implantation in animals. Methods Six miniature pigs of 30-35 kg were selected to laparotomy under intravenous anesthesia. Two to four sterile human stones with a diameter of 0.8-2.0 cm were implanted in their gallbladder. After successful modeling, lumen-apposing metal stent (LAMS) was implanted between the stomach and gallbladder under the guidance EUS. Ultrafine endoscopy was used to search and remove stones after passing the gastric stent into the gallbladder. Endoscopic sphincterotomy (EST) and endoscopic retrogradebiliary drainage (ERBD) was performed to prevent bile leakage. And then ordinary endoscope was used to remove LAMS and close the wound. The success rate, operation time, and incidence of complications were analyzed. Results Five pigs were successfully implanted with LAMS, and the ultrafine endoscope entered the gallbladder smoothly. Small stones were removed from the stone basket, and large stones were completely removed after laser lithotripsy. The total operation time was 87-128 min. No postoperative complications such as bleeding, perforation, infection, and biliary fistula were observed. Failure in 1 pig was due to the first EST plus ERBD, resulting in rapid reduction of gallbladder volume and away from the gastric cavity leading to puncture difficulties. Conclusion EUS-guided LAMS implantation and endoscopic cholecystolithotomy are safe and feasible, and may provide animal experimental evidence for potential therapeutic approach for patients with difficulty in cholecystectomy.
Keywords:Animal experimentation  Cholecystolithiasis  Ultrafine endoscope  Lumen-apposing metal stents  Endoscopic cholecystolithotomy
本文献已被 维普 等数据库收录!
点击此处可从《中华消化内镜杂志》浏览原始摘要信息
点击此处可从《中华消化内镜杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号