Treatment planning considerations of reshapeable automatic intensity modulator for intensity modulated radiation therapy
Authors:Xu Tong  Al-Ghazi Muthana S  Molloi Sabee
Affiliation:Department of Radiological Sciences, University of California, Irvine, California 92697, USA.
Abstract:As compared with multi-leaf collimator based intensity modulated radiation therapy (IMRT) techniques, physical modulators have the major advantage of temporally invariant intensity map delivery which makes it more flexible with monitor unit rate, simpler resolution of interrupted treatment and easier implementation and use with respiratory gating. However, traditional physical modulator techniques require long fabrication time and operator intervention during treatments. It has been previously proposed [Xu et al., Med. Phys. 29, 2222-2229 (2002)] that a reshapeable automatic intensity modulator (RAIM) can automatically produce physical modulators by molding a deformable high x-ray attenuation material using a matrix of computer-controlled pistons. RAIM can potentially eliminate the limitations of traditional physical modulators. The present study addresses the treatment planning considerations of RAIM for IMRT. In this study, a 3D treatment-planning system (PLUNC) was modified to include the capability of providing treatment planning using RAIM. Two clinically representative cases were studied: nasopharyngeal and prostate tumors. First, the RAIM system with two different spatial resolutions at isocenter, 1 x 1 cm2 and 0.5 x 0.5 cm2, were evaluated. The treatment planning results of RAIM were then compared with other IMRT techniques such as smooth modulator with ideal (100%-2%) and limited (100%-13%) intensity modulation ranges, segmental multi-leaf collimator (SMLC) with ten intensity levels, 1 cm leaf width and 0.5 cm step size and serial tomotherapy using the Peacock system. Bringing the spatial resolution of RAIM down to 0.5 x 0.5 cm2 did not show improvement due to the effect of penumbra. The RAIM system with 1 x 1 cm2 proved slightly inferior as compared to the ideal smooth physical modulator but better than the SMLC technique and the smooth modulator with limited modulation range. When compared to serial tomotherapy, RAIM is only inferior in brain stem sparing for the nasopharynx case. Furthermore, the RAIM system with 1 x 1 cm2 resolution required significantly lower monitor units as compared to the other IMRT techniques for the two cases studied.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号