Renal perfusion imaging with multi-slice spiral CT: an experimental study
SUN Jian-nan,GUO Qi-yong,YANG Li-guo,YAO Gang,FANG Jin-hui and YUE Quan. Renal perfusion imaging with multi-slice spiral CT: an experimental study[J]. Chinese Journal of Medical Imaging Technology, 2005, 21(6): 831-833
Authors:SUN Jian-nan  GUO Qi-yong  YANG Li-guo  YAO Gang  FANG Jin-hui  YUE Quan
Affiliation:Department of Radiology, the Second Affiliated Hospital, China Medical University, Shenyang 110004, China;Department of Radiology, the Second Affiliated Hospital, China Medical University, Shenyang 110004, China;CT Division, Daqing Oil Field General Hospital, Daqing 163001, China;CT Division, Daqing Oil Field General Hospital, Daqing 163001, China;CT Division, Daqing Oil Field General Hospital, Daqing 163001, China;CT Division, Daqing Oil Field General Hospital, Daqing 163001, China
Abstract:Objective To evaluate the application of multi-slice spiral CT perfusion imaging in the kidney and the influence of various injection rate on perfusion parameters. Methods Thirty-six health rabbits were randomly divided into three groups (A, B, C), the dose of contrast agent were 2 ml/kg (300 mgI/ml ), the injection flow rate in each group were 1ml/s, 2ml/s, and 3ml/s respectively to make a quantitative analysis for the parameter of renal perfusion imaging. Results Every perfusion parameter was no significant difference not only between group A and group B, but also between group B and group C (P> 0.05 ), but there was a significant difference between group A and group C (P<0.05). Perfusion parameters were significant difference in cortex and medulla of the same kidney (P<0.05). Conclusion Multi-slice spiral CT can provide quantitative analysis to renal blood perfusion, but injection flow rate influence the perfusion parameters.
Keywords:Tomography   X-ray computed  Perfusion  Kidney  Rabbit